Windows Service started, but process vanished in task manager - windows

I programmed a Windows Service and it is running on a Windows 2000 machine. Sometimes the executable for this service dies, but the Windows service is still listed as "started" in the service manager. In this situation the restart behaviour defined for this service does not take effect.
Of course, the process needs to be debugged, but I am searching right now for a workaround.
How can I avoid this situation? How does the service manager in Windows 2000 determine if a windows 2000 process is still started or not?

That probably means that the service crashed. IIRC, older versions of windows didn't always recover when a service process abnormally terminates. But that was many years ago and my memory may be faulty.
The best way to avoid the situation is to figure out what's causing your service to crash and fix it.

Although Larry, being a Microsoft employee, probably knows better than anyone else, I dare say that you should give ChangeServiceConfig2 with SERVICE_CONFIG_FAILURE_ACTIONS a shot. I've worked on a legacy service that, before I did the refactoring, used to crash a lot. The remedy my predecessors chose was to use the failure action in order to invoke a program that (running under SYSTEM) would then restart the service as if nothing had happened.
All of this only works if your service is running in its own process, which I assumed given the way you describe it. If your service is implemented in a DLL this will not work.
But I wholeheartedly agree with Larry that you should investigate and fix the problem, rather than trying to conceal it. As mentioned above, I fixed the service in question and it's not crashing or very rarely crashing and everyone is happier with that solution ;)

Related

Windows 7 Embedded Standard: Do you need to shut it down?

I realise that this may be a silly question, and for that I apologise in advance...
I am developing an application that is going to run on a Windows 7 Embedded Standard device installed in a vehicle. As things currently stand, the device is powered off with the ignition however I am not sure that this is ideal as it means that there is no graceful shutdown.
I have been looking around the web and I cannot find anything that indicates whether Windows 7 Embedded Standard is a special case that does not require a graceful shutdown or whether I have just been lucky to date as I have never seen any "Windows was not shut down properly" messages or anything else to indicate that simply pulling the power has caused any problems. My gut feel (and that of my colleagues) is that we should be performing a graceful shutdown before powering off the device but it would be nice to have some evidence to base that upon.
Can anybody enlighten me here?
Thanks.
Well, we also use WES7 with ungracefull shutdowns, but we are protected from anything.
Have you heard about Enhanced Write Filter ? EWF is a program that prevents any modifications made to the Drive where Windows is installed. It actually writes any change made into the RAM so all these changes are discarded upon reboot.
This has a side effect: on reboot, Windows will not detect it has been shut down ungracefully.
This program is available in the ICE as a package (if I remember).

Killing processes on Windows 7

I'm debugging plugins on Windows 7 and of course the plugin host (Cubase5.exe) occasionally crashes because of errors in the plugin. On XP or Vista, I could always restart it immediately and continue working. But on Windows 7, even though Cubase appears to close, it is still visible in Task Manager and I cannot kill it by any means. After a minute or two, it disappears by itself. In the mean time, I can't work because the plugin DLL is still locked by the process.
Does anyone know why this happens on Windows 7? I've already tried disabling Automatic Error Reporting but that didn't help. I've tried attaching cdb to Cubase, but I get:
Cannot debug pid 5252, NTSTATUS 0xC0000001
"{Operation Failed} The requested operation was unsuccessful."
Debuggee initialization failed, NTSTATUS 0xC0000001
"{Operation Failed} The requested operation was unsuccessful."
I tried following the instructions here but it appears this is only possible if I connect a second machine to my computer to debug it remotely.
I finally found the solution, using this article:
http://blogs.technet.com/b/markrussinovich/archive/2005/08/17/unkillable-processes.aspx
This required installing the Windows Debugging Tools for Windows (nice name) and LiveKd, but by following the steps outlined I was able to track which driver was causing the process to hang: it turned out to be the 64-bit driver for the M-Audio Oxygen 8 V2 controller I'm using. Unfortunately no driver update is available.
Anyway, if anyone encounters a similar problem, this is the way to solve it.
Have you tried Process Explorer by Mark Russinovich? It is really useful for "killing":)
If you have error reporting enabled, it's possible that werfault.exe has Cubase open to write a minidump for crash reporting purposes.
This is just a stab in the dark but it might be your problem.
One thing you can try is to check with Process Monitor what Cubase is doing. Set a filter so that everything with a process name containing "cubase" will be recorded. It could be that you are facing some timeout issue when Cubase wants to exit.
you can end the process the service is running under. You can find this process by going to the Services tab of the Task Manager, right-clicking, and selecting Go To Process(you need to click the Show processes from all users button.). Note that one process may host multiple services (especially if it's svchost.exe), and ending the process will kill all those services. Also, this is an unclean exit, and may cause data corruption depending on what the service(s) was doing when you killed it.
Depending on which specific service you are trying to stop, there may be a cleaner way to simulate failure.

Application error: fault address 0x00012afb (Expert)

I need some "light" to get a solution. Probably there are tons of things that cause this problem, but maybe somebody could help me.
Scenario: a Windows server running 24/7 a PostgreSQL database and others server applications (for processing tasks on database, etc...). There are differents servers scenarios (~30), with different hardware and windows versions (XP SP3/ WinServer, etc... all NT based). All aplications were written in Delphi7, and link to DLLs (in D7 also).
After some days (sometimes a week, sometimes a couple of months), Windows begins to act strange, like not opening start menu, some buttons are missing in dialogs. And soon some applications do not open, raising a event on eventviewer:
Faulting application x, version y, faulting module kernel32.dll, version 5.1.2600.5781, fault address 0x00012afb
In mean while, others applications open fine, like notepad, iexplore, etc... but SOME of my applications don't, with only event log described above. But if we do not restart system, in a few days even cmd.exe stops open, (and all other applications) with same error on eventlog.
I've tried to find 'what' can cause this, but with no sucess. So, and any advice will be welcome.
Thanks in advance.
I think you are running out of resource handles (Window handles). You can verify this by having a look at the system properties in Sysinternals Process Explorer (a better task manager). I think even the default task manager can help out to display a handle count. Then you can identify which application is causing the trouble.
Once you know the application leaking and if it is yours, you can use Rational purify or Boundschecker to drill down to the problem. If you do not have money for these tools you will have to reduce the problem manually a bit by deactivating some features for example and see if the handle count still increases...
Not sure if it is the problem you are experiencing maybe it is completely unrelated. But easy to check. The track is that some app is stealing some global resources as you experience trouble with other applications. Applications like notepad do not use much resources so appear to work fine, heavy apps are more likely to show up the trouble.
Hope it helps.

Identify a reboot

Is there any "Boot session ID" or (reliable) "Boot timestamp"?
For an installation I need to detect that a scheduled reboot took place indeed.
I guess I could do a dummy MoveFileEx() with MOVEFILE_DELAY_UNTIL_REBOOT, but i did hope for something easier.
(We have to install a 3rd party package that sometimes behaves erratically after an repair/update. In that state, accessing the device may even lock up the system)
(Windows XP, Vista, 7)
For things like this, WMI (Windows Management Instrumentation) is often a good starting place. I know you can get current uptime directly through it, which may allow you to determine if a machine recently rebooted.
Here is a blog post with some code samples as well:
http://blogs.technet.com/heyscriptingguy/archive/2004/09/07/how-can-i-tell-if-a-server-has-rebooted.aspx
Depending on your implementation language, you probably just want to pull out the query code from the vbscript.
Apparently Windows has the equivalent of "uptime". Here's more info: http://support.microsoft.com/kb/555737
As I understand it, this should tell you how long ago the system was booted. Will that information solve your problem?
You could search the System event log for event 6009 from the EventLog source - this is the first event recorded after each reboot.
I think the best answer has already been given here: Find out if computer rebooted since the last time my program ran?
That seems to be the simplest way. Use GlobalFindAtom() to see if it exists and create it, with GlobalAddAtom(), if it doesn't. It will persist beyond the execution of your program. If your application runs again, and sees that the atom exists, then then it isn't the first run since reboot.
If the computer is restarted, then the atom won't exist, indicating that this is the first run of your program since the reboot.

Terminating intermittently

Has anyone had and solved a problem where programs would terminate without any indication of why? I encounter this problem about every 6 months and I can get it to stop by having me (the administrator) log-in then out of the machine. After this things are back to normal for the next 6 months. I've seen this on Windows XP and Windows 2000 machines.
I've looked in the Event Viewer and monitored API calls and I cannot see anything out of the ordinary.
UPDATE: On the Windows 2000 machine, Visual Basic 6 would terminate when loading a project. On the Windows XP machine, IIS stopped working until I logged in then out.
UPDATE: Restarting the machine doesn't work.
Perhaps it's not solved by you logging in, but by the user logging out. It could be a memory leak and logging out closes the process, causing windows to reclaim the memory. I assume programs indicated multiple applications, so it could be a shared dll that's causing the problem. Is there any kind of similarities in the programs? .Net, VB6, Office, and so on, or is it everything on the computer? You may be able to narrow it down to shared libraries.
During the 6 month "no error" time frame, is the system always on and logged in? If that's the case, you may suggest the user periodically reboot, perhaps once a week, in order to reclaim leaked memory, or memory claimed by hanging programs that didn't close properly.
You need to take this issue to the software developer.
The more details you provide the more likely it will be that you will get an answer: explain what exact program was 'terminating'. A termination is usually caused by an internal unhandled error, and not all programs check for them, and log them before quitting. However I think you can install Dr Watson, and it will give you at least a stack trace when a crash happens.

Resources