Hey guys,
I have a strange behaviour and am wondering why this happens:
My managed bean holds three values (selected plant, selected year and selected month). When opening the required page a #PostConstruct method is called and initializes the plant data according to the selected/pre defined plant, year and month. When changing one of these three options data should be updated and displayed via AJAX request. In order to switch to edit mode I can click my button and change one value from true to fals which is indicating whether the page should be displayed in view or edit mode.
Now here is my problem:
My local Weblogic Server (IntegratedWeblogicServer - standard configuration) works as expected. I open the page, see my current data, switch to edit mode, edit & save it. That's all. Works like a charm.
The productive Weblogic Server (configured by a colleague of mine) does some kind of cache I think. I open the page, see my current data, change year value to last year and see the updated values. When clicking on the "edit" button the old values are displayed instead of the updated values. This just happens as long as I do not switch the plant. My current workaround looks like this: open the page, switch the plant and then switch the year. After switching the plant everything works like expected. I can't figure out why the productive machine behaves different than the local machine. Each of the update methods setPlant(), setYear() and setMonth() call refreshValues() and are equal requading JSF definitions. So I don't know if it's a caching problem or maybe a Weblogic configuration problem.
Let me know if you need more information or certain code snippets. I excluded them as it is a lot of code.
Kind regards,
Stefi

Enable http headers debug from browser and monitor the difference in each environment. Also monitor the access.log on each domains server.

Related

Missing GA4 event parameters

I have recently started to use Google Analytics 4 for event tracking, using Google Tag Manager to send events to Analytics. I have set up the custom variables in Tag Manager as well as in GA4.
Everything seems to work very well in Tag Manager's debug mode, and also if I look up the events in real-time view I get the requested event along with all the parameters I have set in Tag Manager. However, once I look up the events for the last couple of days in the Engagement -> Event view, a couple of my parameters are missing, and also I'm not getting the same hit count for each parameter, even though each event has all parameters set:
As you can see, 86 events have been recorded, but the event count for the parameters widely varies.
Here's a screenshot of my Tag manager settings:
I have tried to set up a new event with the same parameters, but (logically) I got the same result. I am under the strong impression I'm missing something obvious here. Does anyone have experience with this, or has anyone come across this same issue?
To be honest, you can just try to click on mark as conversion in the Events tab, and this should save them. I think for some reason GA4 doesn't save parameters otherwise...
i cant get this til work with fields and parameters for an event so i try to create a user custom dimension instead and also to send it as a content group and as user property
also i can see the user id under app instance for the standard report user explorer
but i can't filter on or select this one myself
i cant create the custom parameter reports like gerrit did
but yeah create them as custom dimensions /metric first should be the way
ga4 has a bug when you edit a standard report, you add 3 card and deselect one it still thinks you are maxed out and you have to start over...
the test internal users filters dont work, though you can see data in debug and under events, but since i know they work i know try to just make the filters active

How to create a Checkpoint in UFT

Strange enough that I have to ask such a simple question.
I started automating with UFT and I suppose the correct way to check if for instance my login has worked is to add a checkpoint on the next page.
But how do I do that?
All info I get from google is on how to add an already existing checkpoint to may page. But I don't have any.
Here is how I go about automating:
I add manually the relevant objects to the object repository
I create parameters for my action
I create the code that does the steps on the page
one action per page seems to be fine for me
But in the Object Repository of UFT 14.53, there is no button to add a Checkpoint.
A workaround for me would be to just add another Object and check it's existence and forget about checkpoints. Until I hopefully get an answer here, I will try to do just that.
In UFT there are typically two ways to verify that things are working as expected.
Flow (implicit) - In order to verify that progress in the application is successful (e.g. login) one usually just keeps working with the app, assuming that if the previous step failed, the objects needed for the next steps won't exist and the test will fail due to ObjectNotFound errors
State (explicit) - In order to see that objects have a specific state, checkpoints are usually used. Checkpoints are typically added during a record session, I'm not sure if there's a way to add them directly to the repository. An alternative to checkpoints, which works better with keyword driven testing (no recording), is to use the built in CheckProperty method.

coldfusion session variable disappearing

I have a variable, session.acclevel, which is set during the login process (the program is login2.cfm).
<cfset session.acclevel = logdata['LOGACCESS'][1]>
The values can be N,R,W,A,M, and they are retrieved with query name = "logdata" from a table which I'm calling XXX here. If the login is successful, login2.cfm redirects to program navbar.cfm
<cflocation url = "navbar.cfm?welc=yes">
which is a set of dropdown menus, rather like a dashboard. Depending on the value of session.acclevel navbar shows more or fewer options. The session.acclevel variable is also used throughout the system to control various user activities.
All this was working fine, and then it suddenly stopped working -- session.acclevel was fine when navbar started up, but disappeared as soon as any selection was made. Yet, no code had been changed. The only thing I had changed was to alter the MySql table definition of the acclevel` variable type:
alter table XXX change LogAccess LogAccess enum('A','W','R','N','M');
to add the option 'M' to the enum. I did not chnage any data in that table, and I made no changes to the coding anywhere.
I double checked the timeouts (I am using system admin defaults), and tried without success to trace where the variable was getting lost. I closed and reopened the browser, without fixing anything.
Finally I went to the administrator and changed session management to J2EE -- and that fixed it. session.acclevel is now staying put.
Could someone explain what was going wrong there? I would like to know in case this defect in the ColdFusion session management is caused by weak code that I could avoid, or in case it later breaks under J2EE management.

new server/website appears to be caching but cache is turned off

I recently setup a home server running windows 7 pro and IIS 7.5. I have an ASP page that reads/writes to a database. One scenario I have is a newsletter with a list of subscribers. I manually check a box next to a user's name and they get added to a table that associates that userid with a messageid.
When the page loads initially, let's say I've previously added a user to the newsletter. I have a variable that displays that says "1 subscriber". If I add a user (by checking a box next to their name, hitting submit and submitting a form to the same page but with an action=submit added) the user entry will be added to the DB, the script file then redirects to the same page without the action=submit and Session("msg") will show as "updated successfully" but the subscriber count will equal 1 still. If I hit F5, the number updates.
Everything I've read along with what knowledge I have of programming points to it being a caching issue. However, I've taken all the steps I can find online to disable all caching.
Is there something I might be missing or might it not be a caching issue at all but rather something else? I've used this style of programming for years on other servers without any issues which is why I feel like it points to a setting somewhere.
This is the first server, I've been the admin for so I'm kinda bumbling my way through these things as they come up.
subscribers.asp?cid=5
polls DB to pull count of number of subscribers (audience)
[subscribers show 1]
polls DB to pull all email addresses in DB (subscribers)
list available email address within form
I check appropriate checkboxes next to name(s) and submit form
form submits to subscribers.asp?cid=5 with hidden input type name=action value=submit
Script runs (if action=submit then)
insert subscriber ids into audience table
set RS and Conn = Nothing
response.redirect(subscribers.asp?cid=5)
GOTO TOP
subscribers still show as 1. Hit F5, now it shows incremented appropriately.
Any help is greatly appreciated!

How to use internationalization in Label fields in Screens in Oracle Policy Automation

I am very new to Oracle Policy Automation. I am developing a screen which will give the option to the user to select languages. Based on his/her selection, the next screen should display a welcome message in the language selected.
I have two properties files (one for each language) and I have placed them inside the /classes/configuration folder.
Now, my query is how to invoke these properties files based on user selection and what should I write in the label field so that the messages are dynamically picked up.
Thanks in advance for the help.
I guess you may have figured this out by now.
In OPA the locale has to be set at the start of an interactive session (part of the start investigation URL) and cannot be changed subsequently. The locale specific resource files under configuration will then be used.
Your locale selection screen would probably need to be outside of OPA triggering a session start of the correct type. If you are using OWD then it will actually provide it's own locale selection screen if you try to access a rulebase without specifying the locale to use. We are working on some additional tooling around OWD to make this process a lot more straightforward