VHDL st_logic_vector - vhdl

signal test : std_logic_vector(135 downto 0) := x"FC255346D1B5ED025D57B49D1B44D584A1";
this signal corresponds to 'Hello World' on the console. It is not hexadecimal, obviously not binary. What is it ? I am trying to write something different.

FC255346D1B5ED025D57B49D1B44D584A1 is in binary:
111111000010010101010011010001101101000110110...
111111: UART is in high level (no transmission)
0: start bit
00010010: This is 'H' in ASCII binary (LSB first)
1: End of character
010100110: This is 'e' in ASCII binary (LSB first)
etc...

Well it begins X" ..." so it's obviously hexadecimal.
That's not the question, nor is what does it represent? which is obviously "Hello World", but how it represents it.
Figure out what's between it and the console.
If just a shift register, figure out which end comes out first. write out the first 16 bits or so - or draw the waveform - remembering that a console's interface is a UART, which expects start bits, 7 or 8 bit data, possibly parity, stop bits.
Examine these to find out where Ascii "H" is buried and reverse engineer the rest of the spec from that.
Then you'll know what you have to do to substitute another message.
If you pad out the actual data with these other formatting bits in the std_logic_vector, you can replace the transmit part of a UART with a simple shift register - it's a neat hack, moving complexity out of the actual hardware and into something else - Python script or simple VHDL profram - to take a string and convert it to this format - and that's my guess what's happened here.
You might look around the rest of the project to see if you can find that python script or program...

Related

How to binary analyze a Windows exe file?

I want to binary analyze a Windows EXE file without Windows API call (because I will do it from another OS). I want to disginguish 2 x 2 types:
Is it a windowed program or a command line program?
Is it a Win32 or a Win64 program?
I hope that there are general bit structures which I can query.
The link Microsoft PE and COFF Specification was useful, but a little tricky. Here is my result now:
Every Windows program has got a DOS program block showing a text like "This program cannot be run under DOS" or a similar text. The length of the DOS block can differ. The "real Windows program" section begins later. The beginning offset address of the Windows program is coded in the bytes offset 0x3c and 0x3d. 0x3d holds the hi and 0x3c the lo value. So you have to calulate 256*(0x3d) + (0x3c) to get the offset address of the real Windows program.
The real Windows program begins with four bytes: "PE", followed by two nullbytes. The fifth and sixth byte is 0x4c01 if it is a Win32 program and 0x6486 if it is a Win64 program.
To check if the program is textbased, you have to read offset byte (counted from "PE"=0x00) 0x5c. A value of 3 means text based, 2 means a Windowed GUI program.

How do I interpret a python byte string coming from F1 2020 game UDP packet?

Title may be wildly incorrect for what I'm trying to work out.
I'm trying to interpret packets I am recieving from a racing game in a way that I understand, but I honestly don't really know what I'm looking at, or what to search to understand it.
Information on the packets I am recieving here:
https://forums.codemasters.com/topic/54423-f1%C2%AE-2020-udp-specification/?tab=comments#comment-532560
I'm using python to print the packets, here's a snippet of the output, which I don't understand how to interpret.
received message: b'\xe4\x07\x01\x03\x01\x07O\x90.\xea\xc2!7\x16\xa5\xbb\x02C\xda\n\x00\x00\x00\xff\x01\x00\x03:\x00\x00\x00 A\x00\x00\xdcB\xb5+\xc1#\xc82\xcc\x10\t\x00\xd9\x00\x00\x00\x00\x00\x12\x10\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00$tJ\x03\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01
I'm very new to coding, and not sure what my next step is, so a nudge in the right direction will help loads, thanks.
This is the python code:
import socket
UDP_IP = "127.0.0.1"
UDP_PORT = 20777
sock = socket.socket(socket.AF_INET, # Internet
socket.SOCK_DGRAM) # UDP
sock.bind((UDP_IP, UDP_PORT))
while True:
data, addr = sock.recvfrom(4096)
print ("received message:", data)
The website you link to is describing the data format. All data represented as a series of 1's and 0's. A byte is a series of 8 1's and 0's. However, just because you have a series of bytes doesn't mean you know how to interpret them. Do they represent a character? An integer? Can that integer be negative? All of that is defined by whoever crafted the data in the first place.
The type descriptions you see at the top are telling you how to actually interpret that series of 1's and 0's. When you see "unit8", that is an "unsigned integer that is 8 bits (1 byte) long". In other words, a positive number between 0 and 255. An "int8" on the other hand is an "8-bit integer", or a number that can be positive or negative (so the range is -128 to 127). The same basic idea applies to the *16 and *64 variants, just with 16 bits or 64 bits. A float represent a floating point number (a number with a fractional part, such as 1.2345), generally 4 bytes long. Additionally, you need to know the order to interpret the bytes within a word (left-to-right or right-to-left). This is referred to as the endianness, and every computer architecture has a native endianness (big-endian or little-endian).
Given all of that, you can interpret the PacketHeader. The easiest way is probably to use the struct package in Python. Details can be found here:
https://docs.python.org/3/library/struct.html
As a proof of concept, the following will interpret the first 24 bytes:
import struct
data = b'\xe4\x07\x01\x03\x01\x07O\x90.\xea\xc2!7\x16\xa5\xbb\x02C\xda\n\x00\x00\x00\xff\x01\x00\x03:\x00\x00\x00 A\x00\x00\xdcB\xb5+\xc1#\xc82\xcc\x10\t\x00\xd9\x00\x00\x00\x00\x00\x12\x10\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00$tJ\x03\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x00\x01'
#Note that I am only taking the first 24 bytes. You must pass data that is
#the appropriate length to the unpack function. We don't know what everything
#else is until after we parse out the header
header = struct.unpack('<HBBBBQfIBB', data[:24])
print(header)
You basically want to read the first 24 bytes to get the header of the message. From there, you need to use the m_packetId field to determine what the rest of the message is. As an example, this particular packet has a packetId of 7, which is a "Car Status" packet. So you would look at the packing format for the struct CarStatus further down on that page to figure out how to interpret the rest of the message. Rinse and repeat as data arrives.
Update: In the format string, the < tells you to interpret the bytes as little-endian with no alignment (based on the fact that the documentation says it is little-endian and packed). I would recommend reading through the entire section on Format Characters in the documentation above to fully understand what all is happening regarding alignment, but in a nutshell it will try to align those bytes with their representation in memory, which may not match exactly the format you specify. In this case, HBBBBQ takes up 2 bytes more than you'd expect. This is because your computer will try to pack structs in memory so that they are word-aligned. Your computer architecture determines the word alignment (on a 64-bit computer, words are 64-bits, or 8 bytes, long). A Q takes a full word, so the packer will try to align everything before the Q to a word. However, HBBBB only requires 6 bytes; so, Python will, by default, pad an extra 2 bytes to make sure everything lines up. Using < at the front both ensures that the bytes will be interpreted in the correct order, and that it won't try to align the bytes.
Just for information if someone else is looking for this. In python there is the library f1-2019-telemetry existing. On the documentation, there is a missing part about the "how to use" so here is a snippet:
from f1_2020_telemetry.packets import *
...
udp_socket = socket.socket(family=socket.AF_INET, type=socket.SOCK_DGRAM)
udp_socket.bind((host, port))
while True:
udp_packet = udp_socket.recv(2048)
packet = unpack_udp_packet(udp_packet)
if isinstance(packet, PacketSessionData_V1): # refer to doc for classes / attribute
print(packet.trackTemperature) # for example
if isinstance(packet, PacketParticipantsData_V1):
for i, participant in enumerate(packet.participants):
print(DriverIDs[participant.driverId]) # the library has some mapping for pilot name / track name / ...
Regards,
Nicolas

ASCII control of VFD

All,
I am a new user here, and thought I would see if the experts could help me with something I am new to.
I have been given the following statement to try and solve:
The Variable Frequency Drive (VFD) is connected to the PLC by RS485 communication. The speed of the motor (M2) can be adjusted by sending the following command:
STX N DATA ETX , with each separate value having the <> symbols around them.
Data : Length of data is 1 byte, in which the value of S (Slow), M (Medium) or F (Fast) can be sent.
N : Node number of the VFD, with a data length of two byte ASCII.
My question is, how would I type to send this data? It doesn't say whether to use a specific data type to represent, so surely I could just type the data as it is, e.g. STX 1 S ETX?
Othwerside, I'm not sure how to combine the byte representations of the data, representing them in hex, binary or decimal. I'm not sure what is meant by two byte ASCII, is this not UNICODE-16? Also, I'm not sure if I need to send the values of STX or ETX with the data string or not
I hope someone can shed some light on this.
Thanks in advance.
Since the frequency goes from 0-50 Hz, I think we should send data in this range.
So if we want the frequency to be half maximal, we will send 25.
To send this to VFD, we first need to split that number into 2 and 5
The message should read STX 2 5 ETX?
Now we look at the ASCII code table and find 2 and 5.
0x50 = 2
0x53 = 5
We convey everything in a message that reads
STX 0x50 0x53 ETX
The aforementioned S7-300 is recommended for operation. You can also solve this through his TIA portal.
All,
I managed to figure this out with a bit of digging. I simulated it using Siemens S7-300 on TIA portal, and set up communications on a module. I sent the values I wanted using a "move" block, to a value set in the Data Block.
I repeated this for the Node value, making sure the correct data type was chosen, and sent the data through a Send_ptp command block.
Must have got a bit flustered and tired the other night when I was trying it. Hopefully it might help someone in the future.

Arduino serial sometimes gives random values

I am using a MMA7361 accelerometer from sparkfun that is connected to my arduino uno and it is in turn connected to my pc.
I am simply reading the values from each axis(x,y,z) and sending them straight through the serial port to my pc with a series of Serial.print and Serial.write. From there I have set up a program to read and display the info with myPort.readString();
Now it works fine 80% of the time and it gives the right results and all, but sometimes I get some random value sent through the serial port and it messes up the receiving program making me unable to use the signal properly.
I am pretty sure its not the sensor itself sending the disturbing signal because I have tried to save 10 different readings and then sending an average to minimize the effect with no luck. The receiving pc still got the weird value spikes around 0-200 (from what I saw as output).
I tried with pulling out the cable that connects from the sensor to the analog in port and weirdly it gave out some random value instead of the expected 0, I'm not sure but for me it seems like that has something to do about my problem.
I have read about some kind of pull down resistor but that only works for buttons, right?
I just got my arduino and I'm trying to learn how to use sensors and what you can do with them and what can go wrong so I'd appreciate if someone could help me with this :)
Heres an example of the random value messing up the output:
252:236:218
251:202:215
2 <-- this is where it begins
59:231:245
28
4:144:142 <-- messing up the order of the values
251:19
2:187
246:235
:244
240:190:
238
250:202:2
32
248:243:224
245:227:240
251:228:244
253:223:241
If you want I got the code for sending and recieving too:
Serial.print(analogRead(xpin));
Serial.write(":");
Serial.print(analogRead(ypin));
Serial.write(":");
Serial.println(analogRead(zpin));
I'd really like the sending to be just one line of code but I haven't been able to join all numbers and strings to a one line string on the arduino.
Recieving:
if ( myPort.available() > 0) {
result = myPort.readString();
println(result);
}
Looking at your output, it seems that the values are all received, but somehow a CR and/or LF character is added to the output. And that comes from the println statement:
if ( myPort.available() > 0) {
result = myPort.readString();
println(result);
}
What happens is that the receiving end gets some characters (not necessarily all), it prints them, adding a linefeed character then exits the function.
Then it enters the if statement again and prints the available characters in the buffer. And so it goes.
If you wish to ensure a consistent output you have to either
1. build a packet of the data or
2. Count the received bytes and print them when all are received.
As to 1. it would be my preferred method, add a start- and end-character to the data. The receiving end will then know that all data between the start- and end-character is the data to be printed.
I seem to have fixed this by using readChar and checking if the current character inputted is the delimiter. It is a bit slower but it works.

using int64 type for snmp v2c oid?

I am debugging some snmp code for an integer overflow problem. Basically we use an integer to store disk/raid capacity in KB. However when a disk/raid of more than 2TB is used, it'll overflow.
I read from some internet forums that snmp v2c support integer64 or unsigned64. In my test it'll still just send the lower 32 bits even though I have set the type to integer64 or unsigned64.
Here is how I did it:
a standalone program will obtain the capacity and write the data to a file. example lines for raid capacity
my-sub-oid
Counter64
7813857280
/etc/snmp/snmpd.conf has a clause to pass thru the oids:
pass_persist mymiboid /path/to/snmpagent
in the mysnmpagent source, read the oidmap into oid/type/value structure from the file, and print to stdout.
printf("%s\n", it->first.c_str());
printf("%s\n", it->second.type.c_str());
printf("%s\n", it->second.value.c_str());
fflush(stdout);
use snmpget to get the sub-oid, and it returns:
mysuboid = Counter32: 3518889984
I use tcpdump and the last segment of the value portion is:
41 0500 d1be 0000
41 should be the tag, 05 should be the length, and the value is only carrying the lower 32-bit of the capacity. (note 7813857280 is 0x1.d1.be.00.00)
I do find that using string type would send correct value (in octetstring format). But I want to know if there is a way to use 64-bit integer in snmp v2c.
I am running NET-SNMP 5.4.2.1 though.
thanks a lot.
Update:
Found the following from snmpd.conf regarding pass (and probably also pass_persist) in net-snmp doc page. I guess it's forcing the Counter64 to Counter32.
Note:
The SMIv2 type counter64 and SNMPv2 noSuchObject exception are not supported.
You are supposed to use two Unsigned32 for lower and upper bytes of your large number.
Counter64 is not meant to be used for large numbers this way.
For reference : 17 Common MIB Design Errors (last one)
SNMP SMIv2 defines a new type Counter64,
https://www.rfc-editor.org/rfc/rfc2578#page-24
which is in fact unsigned 64 bit integer. So if your data fall into the range, using Counter64 is proper.
"In my test it'll still just send the lower 32 bits even though I have set the type to integer64 or unsigned64" sounds like a problem, but unless you show more details (like showing some code) on how you tested it out and received the result, nobody might help further.