Get Computer Model witn WMIC - vb6

I'm, unable to retrieve the PC model in VB6, the property I request from the query returns empty. I try to emulate the result of this CMD command.
wmic computersystem get model
This is the code I try to use. (I added Microsoft WMI scripting lib 1.2 as a reference in the project).
Function wmiInfo() As String
Dim List
Dim Msg
Dim Object
On Local Error Resume Next
Set List = GetObject("winmgmts:{impersonationLevel=impersonate}").InstancesOf("Win32_BaseBoard")
For Each Object In List
Msg = Msg & "Motherboard Serial Number: " & Object.Model & vbCrLf
Next
MsgBox Msg
end function
I expect the function to retrieve just a string with the model of the PC something like "Optiplex 790" (it is what the cmd command returns).
Any help is greatly appreciated.
(OS Windows 7)

I found the issue. I was requesting the wrong class.
Win32_computerSystem has the property I'm looking for.
Function wmiProcessorInfo() As String
Dim msg As String
Dim cpuSet As SWbemObjectSet
Dim cpu As SWbemObject
Dim itmx As ListItem
On Local Error Resume Next
Set cpuSet = GetObject("winmgmts:{impersonationLevel=impersonate}").InstancesOf("Win32_ComputerSystem")
For Each cpu In cpuSet
msg = cpu.Model
Next
MsgBox msg
End Function

Related

Get running instance of application from WMI process?

I'm trying to get hold of running instances of MS Access 2010+ (on Win10) but the usual tip; GetObject(, "Access.Application") ... for works only for hidden instances started by myself with script, but not any instances started from GUI by the user.
And yes, I've read perhaps ten or more google hits on the subject, both on WMI and GetObject, but I seem to have missed something important.
However, I've tried the code below and I can get hold of any process of running Access instances in this way, and I can even .terminate() them, but, that's not what I want to do. Instead I want to grab the process and assign it to a usable (correct type) Access variable (see "OutInstance" in the code below) :
[Edit: Using WHERE clause, and skipped Exit as to retrieve the last instance]
Public Function GetRunningInstance(sAppName sComputer, ByRef OutInstance)
Dim oWMIService
Dim wProcesses
Dim oPrc
GetRunningInstance = False
Set OutInstance = Nothing
if sComputer = "" then sComputer = "."
Set oWMIService = GetObject("winmgmts:" & "{impersonationLevel=" & _
"impersonate}!\\" & sComputer & "\root\cimv2")
Set wProcesses = oWMIService.ExecQuery ("SELECT * FROM Win32_Process " & _
"WHERE Name = '" & sAppName & "'")
For Each oPrc in wProcesses
''' oPrc.Terminate() ''' Works, I can shut down Access...
Set OutInstance = oPrc
GetRunningInstance = True
''' By not exiting we get the last instance.
Next
End Function
Now, after trying to get hold of an instance, how do I "cast" the process to a usable Access application variable in this VBScript?
Sub Test_DoStuff()
Dim InstProc
Dim AccessApp
If GetRunningInstance("msaccess.exe", "127.0.0.1", InstProc) Then
Set AccessApp = ''' cast 'InstProc' to my "Access.Application" somehow?
Else
Set AccessApp = CreateObject("Access.Application")
End If
'''
''' Doing my stuff
'''
AccessApp.CloseCurrentDatabase
AccessApp.DoCmd.Quit
End Sub
Test
I (also) don't understand why GetObject(, "Access.Application") doesn't work in all cases. Permissions? (I understand that it's 'unsafe' to close a database currently being used by a user, but also that can be dealt with).
// Rolf

WMI Query and VB6 error

I'm developing a routine using VB6, you must refresh the screen each second, searching for a specific process running on the system.
I'm using WMI to query processes. But sometimes I get a return "not found", and the application closes. the question is, I can filter the user inside the WMI query using a join or something?
below is my source code
Dim UserName As String
Dim UserDomain As String
Dim proc_query As String
Dim proc_results As Object
UserName = Environ("USERNAME")
proc_query = "select * from Win32_Process where Name = 'Exe1234.EXE'"
Set proc_results = GetObject("Winmgmts:").ExecQuery(proc_query)
For Each info In proc_results
colProperties = info.GetOwner(strNameOfUser, strUserDomain)
If strNameOfUser = UserName Then
// Call a external .exe
Unload Me: Exit For
End If
Next info

Winsock Error 429: activeX component can't create object

So I know that my code below works. The purpose is to create a tcp Ethernet connection between a scale and computer, so that when a weight is read on the scale, the value is displayed on the computer at the push of a button. I copied this code to a new lab machine that was just imaged for me. As for the winsock, I dynamically created it at run-time by adding it to the references. I understand that this is not what I am supposed to do (see: https://support.microsoft.com/en-us/kb/313984).
With a breakpoint at the CFixPicture_Initialize function, the code hits "set tcpC = new Winsock" line and breaks with error 429: avtiveX componenet can't create object. Does anybody have any ideas as to how I can get this license/get this Winsock control to work? Thanks!
Option Explicit
Private WithEvents tcpC As Winsock
Private Sub CFixPicture_Close()
Set tcpC = Nothing
End Sub
Private Sub CFixPicture_Initialize()
Set tcpC = New Winsock
tcpC.LocalPort = 0
tcpC.Connect "192.168.0.1", 8000
End Sub
Private Sub CommandButton1_click()
On Error GoTo errHandler
tcpC.SendData "S" & vbCrLf
Exit Sub
errHandler:
MsgBox "error:" & Err.Description
End Sub
Private Sub tcpC_DataArrival(ByVal bytesTotal As Long)
Dim strData As String
Dim strDataString As String
tcpC.GetData strData
strDataTrim = Mid(strData, 11)
Text1.Caption = "Weight: " & vbCrLf
The control is not present or is present but not registered on the new machine.
Copy over mswinsck.ocx from your *system directory to the new machines *system directory
Open a console as admnistrator and run regsvr32.exe c:\whatever\mswinsck.ocx
*\System32 or \SysWoW64 on 64 bit Windows.
As there was no license for the Winsock, I found a license online. I simply ran this program and voila! The Winsock worked. Thanks!
http://www.planet-source-code.com/vb/scripts/ShowCode.asp?txtCodeId=4860&lngWId=1

Example VB6 code for Siemens OPC Client?

I am trying to update an ancient VB6 project to enable communication with a remote OPC Server. I have installed the Siemens toolkit but I am unable to find any useful documentation on how to use it with VB6. (Works with C#)
The application is very simple. I just need to connect to the remote server and write/read single addresses.
I found the DatCon OCX control which I assume handles the communication but all the ServerName values I tried to enter by hand did not work.
Can anyone help?
Add a reference to the DLL or OCX (the seimens toolkit) to your VB6 project and then use the object browser to browse around the exposed objects. You can often times figure out what you need just be doing that.
The C# docs should also provide a wealth of info. If the library is a COM library, you'll use it essentially the same way from VB6.
Since posting, I did make some progress. The following example helped me to get going.
http://support.automation.siemens.com/WW/llisapi.dll?func=cslib.csinfo&objId=25229521&load=treecontent&lang=en&siteid=cseus&aktprim=0&objaction=csview&extranet=standard&viewreg=WW
Here is my current code. It's not much - just makes contact with the server and tries to write a value. I didn't get any further. I started getting COM errors and assumed the installation was bad (I had had problems installing) so I decided to reinstall. It didn't work. Installation was impossible. Waiting for an upgrade from Siemens.
'
' OPC Communication
'
' Paul Ramsden 24.11.2011
'
'
Option Explicit
Option Base 1
Public MyOpcServer As OPCServer
Public ServerHandle As Variant
Private ServerName As String
Private ServerNode As String
Private TestGroup As OPCGroup
Private MyOpcItem As OPCItem
Private IsInitialised As Boolean
Public Sub InitialiseOPC()
On Error GoTo ProcError
IsInitialised = False
Set MyOpcServer = New OPCServer
ServerNode = "xyz.abc.10.101"
ServerName = "OPC.SimaticNET.1"
Dim LocalServers
LocalServers = MyOpcServer.GetOPCServers(ServerNode)
Dim tmp
ServerHandle = ""
For Each tmp In LocalServers
If CStr(tmp) = ServerName Then
Call MyOpcServer.Connect(tmp)
MsgBox MyOpcServer.ServerNode & vbCr & MyOpcServer.ServerName & vbCr & MyOpcServer.ServerState
ServerHandle = tmp
Set TestGroup = MyOpcServer.OPCGroups.Add("TestGroup")
Exit For
End If
Next
If ServerHandle = "" Then
MsgBox "Could not find server " & ServerName & " on " & ServerNode
Else
IsInitialised = True
End If
ProcExit:
Exit Sub
ProcError:
MsgBox Err.Description
Resume ProcExit
End Sub
Private Sub ClearGroup()
Dim handles() As Long
Dim errors() As Long
Call TestGroup.OPCItems.Remove(TestGroup.OPCItems.Count, handles, errors)
End Sub
Public Sub WriteOPC(address As String, value As String)
On Error GoTo ProcError
Call ClearGroup
Set MyOpcItem = TestGroup.OPCItems.AddItem(address, 2011)
MyOpcItem.Write (value)
Exit Sub
ProcError:
MsgBox "Write error! " & Err.Description
End Sub
Public Function ReadOPC(address As String) As String
On Error GoTo ProcError
Call ClearGroup
Set MyOpcItem = TestGroup.OPCItems.AddItem(address, 2011)
Dim value As String
ReadOPC = MyOpcItem.Read
ProcError:
MsgBox "Read error! " & Err.Description
End Function
Public Sub TestOPC()
InitialiseOPC
WriteOPC "SIMATIC 300(1).CPU 315-2 DP.Q0_0TestAusgang1", "1"
End Sub

Winsock downloading files - vb6

I'm trying to use Winsock to download some files and save them.
In my case, I have a MSHFlexGrid with 2 columns: one with URL and the other with the "path+filename" (where the file is going to be saved).
I'm iterating through all rows calling the next function:
Public Function DownloadSock(ArqURL As String, ArqDestino As String) As Boolean
'ArqURL is the file URL
'ArqDestino is where the downloaded file is going to be stored, in my hard disc
Dim arquivo() As Byte
Dim ficheiroID As Integer
ficheiroID = FreeFile
On Error GoTo Trata_erro
Open ArqDestino For Binary Access Write As #ficheiroID
Me.Winsock1.Connect ArqURL, 80
Me.Winsock1.GetData arquivo()
Put #ficheiroID, , arquivo()
Close #ficheiroID
DownloadSock = True
Exit Function
Trata_erro:
MDIForm1.Text1 = MDIForm1.Text1 & "Error! " & Err.Number & Err.Description & " - " & Err.Source & " - URL: " & ArqURL & " - Destino: " & ArqDestino & vbNewLine
DownloadSock = False
End Function
I'm getting this error
40006: Wrong protocol or connection
state for the requested transaction or
request
What am I doing wrong?
Have you checked out this Microsoft Support page? It indicates there's a bug in the Winsock control and the hotfix may be helpful.
Another thing to try is to make sure your winsock connection is open before trying to read/send data, and if it is closed, reopen a new connection:
if winsock.state=9 ' error state
winsock.close
while winsock.state<>0 ' closed state
doEvents
wend ' you need a while loop, because it doesn't close "immediately".
end if
' now you reopen it, or do whatever else you need
You might also consider changing your connection code to something like:
With Winsock1
If .State <> sckClosed Then .Close
.RemoteHost = ArqURL
.RemotePort = 80
.Connect
End With
One last thing. Check out this post on using the Winsock control.
I think you have overestimated the power of the Winsock control. You can't just use the Winsock's GetData method to reach out and grab a file. There has to be an active connection between your client application and some other application on the server side. After a connection is established, this server application will feed data to your application, the Winsock's DataArrival event will fire, and then you can use the GetData method to retrieve it. Your code should look more like this:
Public Sub DownloadSock(ArqURL As String)
Dim arquivo() As Byte
Dim ficheiroID As Integer
ficheiroID = FreeFile
Me.Winsock1.Connect ArqURL, 80
End Function
Private Sub Winsock1_DataArrival(ByVal bytesTotal As Long)
Dim ArqDestino As String
Dim arquivo() As Byte
Dim ficheiroID As Integer
ficheiroID = FreeFile
Open ArqDestino For Binary Access Write As #ficheiroID
Me.Winsock1.GetData arquivo()
Put #ficheiroID, , arquivo()
Close #ficheiroID
End Sub
This is far from complete however (nor is it guaranteed to be syntactically correct, consider it pseudo code). After making the connection, you then have to implement some mechanism to tell the server to begin sending the file. If the file is large enough it will take many DataArrival events to get it all, so it will have to be held in an accumulator while the data comes across. There's more to this than you think.
I would take a look at some tutorials and/or sample code (look for a VB6 project that uses the Winsock control on CodeProject, like this one).

Resources