TerminalServer Property in MSI Installers - windows

we are trying to create an MSI Installer for an app which under Windows Server 2003. The app needs users to be able to log on via Remote Desktop. Using the "TerminalServer" property looked like the correct test to ensure that's the case, but this returns "false" on machines which do have the right OS with Terminal Service running and which allow users to connect remotely.
What are we missing here?
Thanks!
Armin

IIUC, you actually do need Terminal Services installed and "on"; remote desktop might not be enough. Try also RemoteAdminTS. MSI documentation suggests they are mutually exclusive.
Run the MSI file with /l*v to find out what properties are set to what values.

Related

How to I create a Windows service from a script, run as administrator

I have a Windows installer script for a Windows application I'm delivering to customers. I want to have the application installed as a Windows service.
I've been reading up on various ways to do this. The closest I've found that can do this from a command is sc.exe as described in Create windows service from executable here at Stackoverflow, but this command requires running it as administrator, which as far as I can tell, also requires submitting an administrator's password.
In my build script, there's no way to right-click and "run as administrator".
Is there any way to do this from a build script (I'm using my company's installation packager to do this, which uses Ant-like XML build files with an command and statements -- so, much like running at the Windows command line). If I could figure out a command-line implementation that my customers can use I could give them this package.
Thanks for any tips.
Scott

What is the 2014 way to centrally deploy agents

I'm getting requests from 'the Field' to make my agent deployment 'easier' but I'm at a loss as to how.
Right now, I provide a user Interface to install and configure the agents.
To deploy the agents, I relied on older Windows technologies, here are the steps I use:
Start dependent services via remote SCM
Copy the agent.MSI via the File Administrative shares
Configure the agent's settings via remote registry calls
Use WMI to remotely silently run the agent.msi
Use the Administrative shares to move the agent.msi to the program folder (for uninstalling later)
To allow all these steps to happen, I need:
1. the firewall to configured correctly
2. the 'installing' user has to have admin access to the remote computer
3. Remote File Admin shares have to be turned on.
4. (I turn on WMI and Remote Registry remotely)
This deployment system was built back in the 2003 days.
Is there some better way now? Maybe a deployment library I can use?
thank you.
The best you can do here is to create a properly behaving .MSI that supports silent installation. It is then up to your user communities to plan their own deployments using the tools of their choice such as SCCM. Much more detail is required in order to give exact suggestions.

Create elevated console/cmdline app windows - suggestions?

Looking for suggestions on how to go about the following, i.e what would be the best language to do it in etc, third party tools are a no :(
I've been tasked to create some sort of windows shell/command line interface that will allow a standard users to install a specific set of applications (configurable by administrators) (installation requires Admin/UAC elevation) due to security restrictions the user cannot have elevated privileges so they'll be able to run the shell as a standard user and it would have hidden/encrypted credentials built in to run the installs as.
Some of the requirements are as follows:
It would need to work on Server 2008 R2, 2012 r1 and 2012 r2
The credentials used to perform the install would have to be hidden (encrypted) from the end user.
Ideally it could work by us providing some config to it prior to handing that server over to the customer and limit what it could be used to install to a particular .exe or .msi (so we know of a need to install an app, we are advised of the name of the install and can logon and can enter it into a form maybe so only that app can be installed, then hand the server over to the customer who runs the same utility or shell extension or whatever and can then install their app.
Even more ideally it was more intelligent than that and some means of ensuring any .msi was indeed installing the application that the msi name related to (seems unlikely but just in case a normal user created an .msi to grant himself further admin access as per http://blogs.technet.com/b/fdcc/archive/2011/01/25/alwaysinstallelevated-is-equivalent-to-granting-administrative-rights.aspx )
Ideally its lifespan would be limited in terms of time (unsure if this could be for example to x number of days).
Any pointers on how to go about this, seems like a good challenge :)
Thanks for reading all that!
Mike
Thanks for the responses,
I managed to do this in C#, with no prior experience in the language :)
The application has 2 parts to it, a GUI and a service. It works by having the application send an install command via IPC to it's counterpart elevated service. (Thanks Hans Passant for pointing me in the right direction there). The service initiates the installer under it's own elevated account but displays the installer GUI on the users session. Files are HMACSHA1 checksum validated prior to install, on both the app and the service.
Thanks,
Mike
If a user requires the ability to install application in the Program Files folder, then instruct the domain administrator to give Full Control of the Program Files folder to Everyone:
Just because the default setting forbids standard users from modifying programs, doesn't mean you have to keep it that way. Windows is a secure operating system that gives you the capability to keep it secure.
If your administrator only wants some users to be able to modify the contents of the Program Files folder, then only give that permission to certain users.
The better solution is to re-design the applications so that they do not install in a (by default) protected location. Have them instead install in:
%APPDATA_LOCAL%\Contoso\Frobber\Grob.exe
e.g.
D:\Users\Ian\AppData\Local\Contoso\Frobber\Grob.exe
A user is always allowed to write anything in their own profile folder.

Installing services remotely

Is there a way to install services remotely, without necessarily resorting to .msi packages or full-blown installers? I'm currently using a method similar to the one discussed here:
How to install a windows service programmatically in C#?
to install a service locally, and it works fine. However, I also need to be able to do the same thing remotely. I appreciate any insight.
If you can copy the service binary (the exe file) to the destination computer you can install the service exactly in the same way as you do this locally. The only distinguish is that during the usage of OpenSCManager function (see http://msdn.microsoft.com/en-us/library/ms684323.aspx) you should use destination computer as the first parameter (lpMachineName) and in CreateService (see http://msdn.microsoft.com/en-us/library/ms682450.aspx) as a lpBinaryPathName you should place the path to your service exe how it looks like on the remote computer.
You can use sc.exe utility to do the installation (type" sc create /?" in the command prompt to receive help). The remote installation of the service which you can do with sc.exe you can implement with native Windows API like I short explain above.

WiX 3.0 throws error 217, while being executed by continuous integration

This is the error that is thrown by our automated build suite on Windows 2008, while running ICEs (after migrating from WiX 2.0 to WiX 3.0):
LGHT0217: Error executing ICE action 'ICE01'. The most common cause of this kind of ICE failure is an incorrectly registered scripting engine. See http://wix.sourceforge.net/faq.html#Error217 for details and how to solve this problem. The following string format was not expected by the external UI message logger: "The Windows Installer Service could not be accessed. This can occur if the Windows Installer is not correctly installed. Contact your support personnel for assistance.". in light.exe(0, 0)
The FAQ is now deleted, however, the text from it said:
In WiX v3, Light automatically runs validation-- Windows Installer Internal Consistency Evaluators (ICEs) --after every successful build. Validation is a great way to catch common authoring errors that can lead to service problems, which is why it’s now run by default. Unfortunately, there’s a common issue that occurs on Windows Vista and Windows Server 2008 that can cause ICEs to fail. For details on the cause and how to fix it, see Heath Stewart's Blog and Aaron Stebner's WebLog.
Additionally, these are the errors that show up in the event log:
MSIInstaller: Failed to connect to server. Error: 0x80070005
Product: [ProductName] -- Error 1719. The Windows Installer Service could not be accessed. This can occur if the Windows Installer is not correctly installed. Contact your support personnel for assistance.
Intuitively:
VBScript and JScript were registered under admin.
Integration service has permissions for the desktop interaction and all the files
Builds succeed, when executed manually on the same machine by another user or even user logged in as integration account (via RDP)
I'm out of ideas so far.
How do I solve this problem while keeping ICE validation?
End of the story:
After fiddling with the permissions of the integration account, DCOM, service activation, etc. without any luck, I finally simply disabled ICE validation in the continuous integration build, while still keeping it in the local build.
To disable ICE validation you can set SuppressValidation to true in the .wixproj file:
<PropertyGroup>
<SuppressValidation>true</SuppressValidation>
</PropertyGroup>
Or pass the -sval command line option to light.exe.
Adding the TFS build controller account to local admin group and restarting the windows service did the job for me.
I found the root cause. I tried everything I found, including custom validator extension similar to one posted in Re: [WiX-users] light.exe failed randomly when running ICEs..
It's not a concurrency issue as suggested in various threads. It's caused by a too large Process Environment Block (PEB).
It turns out Windows Installer can’t handle a process environment block larger than 32 kB. In my environment, due to number of variables set by the build system and their size (for example, PATH variable containing multiple duplicated values), PEB was about 34 kB.
Interestingly, per Environment Variables, Windows XP and 2003 had a hard limit of PEB set to 32 kilobytes. That would probably cause an easy-to-catch build break in an earlier phase of the build. Newer Windows' doesn’t have such limit, but I guess that Windows Installer developers limited their internal environment buffers to 32 kB and fail gracefully when the value is exceeded.
The problem can be easily reproduced:
Create a .bat file which sets environment variables which size exceeds 32 kB. For example, it can be 32 lines of set Variable<number>=<text longer than 1024 characters>
Launch cmd.exe
Execute the batch file you created
From the same cmd.exe window:
Try building the MSI package using WiX with ICE validation on OR
Run smoke.exe to validate your package OR
Simply run msiexec /i Package.msi
All the above commands will end up reporting Error 1719 - Windows Installer could not be accessed.
So, the solution is - review your build scripts and reduce number and size of environment variables so they all fit into 32 kB. You can easily verify the results by running:
set > environment.txt
The goal is to get file environment.txt smaller than ~30 kB.
The correct description (without a solution, except if adding the CruiseControl account into local administrators group can pass as a solution) of the problem:
Quote from Wix 3.5 & Cruise Control gives errorLGHT0217:
ICE validation needs an interactive account or administrator privileges to be
happy. See for example WiX Projects vs. TFS 2010 Team Build (2009-11-14) or Re: [WiX-users] Help with building patch (2009-11-20).
imagi is totally right! I could not believe this is the true answer. Supressing validation and making TFS user Administrator are not good solutions. Plus I could not find NT\Authority to add it to Administrators group and was totally stuck in this.
I got the same error on Windows Server 2012 Datacenter as Build Agent.
To solve the problem :
List item
Go to Environment Variables on the build agent machine
Create two System Variables
"PF86" which is equal to "C:\Program Files (x86)"
"PF" which is equal to "C:\Program Files"
They are so short because I want to save characters.I made them without the final backslash because TEMP, TMP and others were made so and I decided to stick to MS standard for these variables.
Edit PATH variable by substituting every "C:\Program Files (x86)" with %PF86% and every "C:\Program Files" with %PF%
Close and build and enjoy!
It worked for me. :)
UPDATE
I found a better solution : Rapid Environment Editor will do all this and even more for you. Automatically.
I faced the same problem and did not like to suppress ICE validation. My setup: I used my own computer as a build agent on Visual Studio Online (VSO). My solution was to change the account used to run the service on my machine. Instead of using Network Service or Local Service I simply made the service log on with my own account which had all the necessary rights.
From http://wix.sourceforge.net/faq.html#Error217:
In WiX v3, Light automatically runs validation--
Windows Installer Internal Consistency Evaluators (ICEs)
--after every successful build. Validation is a
great way to catch common authoring errors that can lead to service problems,
which is why it’s now run by default. Unfortunately, there’s a common issue
that occurs on Windows Vista and Windows Server 2008 that can cause ICEs to
fail. For details on the cause and how to fix it, see
Heath Stewart's Blog
and
Aaron Stebner's WebLog.
I was getting same ICE error, but the problem turned to be corrupted Windows Installer Service.
This solution worked for me:
http://support.microsoft.com/kb/315353
Log on to your computer as an administrator.
Click Start, and then click Run.
In the Open box, type cmd, and then click OK.
At the command prompt, type msiexec.exe /unregister, and then press ENTER.
Type msiexec /regserver, and then press ENTER.
Restart Windows
Also, verify that the SYSTEM account has full control access permissions to the
HKEY_CLASSES_ROOT hive in the Windows registry. In some cases, you may also have to add Administrator accounts.
I have some suggestions.
Try updating the Microsoft Installer version on the build server
Make sure you use the newest release of WiX 3.0, since it's 3.0 release stable now.
If all else fails, try running the build service under a specific build user who you can fiddle with permissions for...
I got this error from my Azure build agent running on-premises.
My solution was to upgrade its user account from "Network Service" to "Local system account".
Go to your build machine and restart the Windows Installer service
None of the above suggestions worked for me, for me the anti-virus (mcafee) came into the picture and looks like it updated the vbscript.dll registry entry to a wrong DLL location. These are the things to keep in mind:
Some of the WiX ICE validations are implemented using VBSCRIPT.
So while compiling the MSI, the build server would need access to the c:\windows\system32\vbscript.dll.
Chances are that somehow the user that runs your build lost access to this DLL.
As mentioned in the above answers do look for the admin access/registry access and make sure your user has it.
Here are the steps that I took to fix the issue:
Open cmd (run as admin) on the build agent machine.
Run RegEdit
Select the root, then click ctrl + f and Search for the following registry entry : {B54F3741-5B07-11cf-A4B0-00AA004A55E8}
Look for the InprocServer32\Default Key
On my build agent, the path was replaced with a mcafee DLL location. I updated the path back to c:\windows\system32\vbscript.dll
Editing the registry entry was not easy, as it was a protected registry entry. I used the below link to get access permissions changed before I could edit the property: Edit protected registry entry
Once I updated the path, everything started working as usual.
My solution is similar to Vladimir's one. My CI user was admin of the computer.
But the following steps were mandatory to allow my jenkins build to succeed:
log in as CI user using rdp
open a dos command prompt
execute: %windir%\system32\msiexec.exe /unregister
execute: %windir%\system32\msiexec.exe /regserver
then i got a successfull job

Resources