Error: Invalid number format while sending SMS with SIM800L - sms

I'm using a SIM800L GSM module connected over USB-Serial to my computer.
When I try to send a SMS I got an error:
AT+CMGS="+4915xxxxxxxxx"
> Test (Ctrl+Z)
+CMS ERROR: Invalid number format (incomplete number)
I’m obviously connected to the network because pin is entered +CREG an +COPS seems good.
AT+CPIN?
+CPIN: READY
OK
AT+CREG?
+CREG: 0,1
OK
AT+COPS?
+COPS: 0,0,"O2 (Germany)"
OK
As well I can receive SMS and see incoming calls.
I set the module in sms text mode and use the coding GSM
AT+CMGF?
+CMGF: 1
OK
AT+CSCS?
+CSCS: "GSM"
OK
I try different number formats like "015xxxxxxxxx" or "004915xxxxxxxxx". Also I try different values for the optional parameter from +CMGS
Could anybody advise me what to do?

To send SMS it was necessary for me to change the SMSC adress with the command AT+CSCA.
AT+CSCA="+491760000443",145
The SMSC you can found at your mobile operator. In my case Netzclub at O2 Germany.

Related

How to retrieve the parts of the same long SMS received from the AT+CMGL command

I have an application interfaced with a GSM Modem where I receive many SMS and display them in a user interface using AT+CMGL command in text mode.
When I have short messages, everything is fine. I can retrieve all messages.
AT+CMGL="ALL"
+CMGL: 0,"REC UNREAD","+111111","","23/01/03,16:57:38+04"
This is message 1
+CMGL: 2,"REC UNREAD","+111111","","23/01/03,16:58:03+04"
This is message 2
+CMGL: 1,"REC UNREAD","+111111","","23/01/03,16:58:04+04"
This is message 3
OK
When I have long messages divided in many parts, because an SMS has a limited number of characters, I see them like many short messages.
AT+CMGL="ALL"
+CMGL: 0,"REC UNREAD","+111111","","23/01/03,18:16:20+04"
This is message 1 : message 1 message 1 message 1 message 1 message 1 message 1 message 1 message 1
+CMGL: 1,"REC UNREAD","+111111","","23/01/03,18:16:21+04"
This is second part of message 1
+CMGL: 2,"REC UNREAD","+111111","","23/01/03,18:19:04+04"
This is message 2
OK
Is there an indication (a parameter in AT+CMGL command) that show me all parts of the same message.
How can I retrieve all parts of the same Message so I can regroup them and display it in my user interface.
Thank You in advance for your time and your help :)
Best regards!
The AT+CMGL command has two modes, text mode and PDU mode. The technical name for splitting up long messages into several "normal" length sms messages is multi-part. AT+CMGL only supports multi-part in PDU mode.
For more details see the 3GPP 27.005 specification.

Unable to receive URC for an incoming SMS from a modem

I have an issue in being unable to recive the URC message from the modem whenever it receives an SMS.
I know that it receives them since i can find and read them if I use AT+CMGL but, i don't receive any notification when the modem gets them. I played around with the URC related commands but I've been unable to get it to work (other URCs work fine).
The modem is a BG600L M3 from Quectel and following is the sequence of commands i'm sending ("AT" is always omitted and the first command is literally "AT\r", basically an empty one).
//general config
AT\r
CFUN=1,0
E1
+QCFG=\"urc/ri/other\",\"pulse\",8,1
H0
&F
V1
+CMEE=1
&D0
E1
+CREG=2
+CGREG=2
+CEREG=2
//sms config
+CPMS=\"ME\",\"ME\",\"ME\"
+QINDCFG=\"smsincoming\",1
+CMGF=1
+CSDH=0
+CSCS=\"GSM\"
+CNMI=2,2,0,2,0
//doing some deleting and reading
+CMGD=1,3
+CPMS?
//getting the gps fix
+QGPS=1
+QGPSCFG=\"gnssconfig\",3
+QGPSLOC=1
+QGPSEND
//resetting the gms connection
+CFUN=0
+CFUN=1,0
//setting up the gsm connection
+QICFG=\"dataformat\",0,0
+QICFG=\"viewmode\",0
+QICFG=\"recvind\",1
+QICFG=\"tcp/retranscfg\",3,600
+QISDE=0
+QCFG=\"band\",0xf,0x80085,0x80085,1
+QCFG=\"nwscanmode\",1,1
+QCFG=\"nwscanseq\",010101,1
+QCFG=\"iotopmode\",2,1
// checking if it's connected
+CREG?
+QNWINFO
+COPS?
//Getting the time
+CTZU=3
+CTZR=0
+QLTS
+CCLK?
You can set AT+CNMI=2,1,2,0,0 , that should do the trick.
According to specification ETSI TS 127 005 V11.0.0 (2012-10)
+CNMI: <mode>,<mt>,<bm>,<ds>,<bfr>
by keeping <mt> value to 1 we should get indication when message is stored in ME/TA
<mt>: integer type (the rules for storing received SMs depend on its
data coding scheme
0 No SMS-DELIVER indications are routed to the TE.
1 If SMS-DELIVER is stored into ME/TA, indication of the memory location is routed to the TE using unsolicited result code:
+CMTI: <mem>,<index>

ZPL ^HS command gives incorrect value for number of formats in receive buffer

I am trying to get the number of label formats remaining in the print buffer of a Zebra printer. The printer is being accessed using the Zatar cloud service. To achieve this I am:
putting the printer in a paused state
calling the ^HS command
looking at the 5th field in string 1 of the response
According to the ZPL documentation this field is the
number of formats in receive buffer
However, this value does not appear to be correct. Each subsequent time we call it whilst the printer is paused the value in the field increases. No other jobs are being sent to the printer.
Here is same output of the response:
DEVICE_COMPLETED_SUCCESSFULLY - 030,0,1,0834,003,0,0,0,000,0,0,0
000,0,0,0,0,2,6,0,00000001,1,001
1234,0
Then this after a short interval:
DEVICE_COMPLETED_SUCCESSFULLY - 030,0,1,0834,026,0,0,0,000,0,0,0
000,0,0,0,0,2,6,0,00000001,1,001
1234,0
And so on:
DEVICE_COMPLETED_SUCCESSFULLY - 030,0,1,0834,028,0,0,0,000,0,0,0
000,0,0,0,0,2,6,0,00000001,1,001
1234,0
The initial response of 003 is correct. However I do not understand why it is then incrementing to 26 and then to 28.
Why is the response not providing the correct value for the formats remaining in the receive buffer?
The reason for the discrepancy in the number of formats in the receive buffer was due to how the printer was being accessed. The Zatar cloud service was used rather than any direct method such as USB.
The Zatar cloud service uses a device called an Edgebox to communicate with the printer. The Edgebox was periodically sending commands to the printer and it was these commands that were accumulating in the receive buffer.

APNS response packet returning the wrong identifier

I'm getting an odd error when using APNS under production.
Whenever I send a notification that errors (for example the device token becomes invalid), the response packet returned is correct, except that the identifier is 1 less than the identifier I sent. However, on production the correct identifier is returned.
For example: I send a notification with ID 108. But I receive a packet back:
8 8 0 0 0 107
The first byte will always be 8
The second byte is the status code; in this case meaning the device token isn't valid
The last 4 bytes are the identifier
For convenience, here is Apples documentation on the subject.
http://developer.apple.com/library/ios/#DOCUMENTATION/NetworkingInternet/Conceptual/RemoteNotificationsPG/CommunicatingWIthAPS/CommunicatingWIthAPS.html#//apple_ref/doc/uid/TP40008194-CH101-SW4
Is anyone else seeing this problem, or is it likely something I've done wrong.
Many thanks in advance.

wings communication server: submitsm command status 0x14

Has anyone had experience with this tool (WCS). Some sms messages are not being sent. The log says:
2007-04-14 10:59:53,490 [logica-smpp2-receiver] ERROR logica-smpp2 - Message not sent, SubmitSM command status: 0x14
If I've read the specs correctly, command status 0x14 means "message queue full".
I suggest:
- Try spreading the messages over a longer period
- Ask your SMPP provider what the limits are, how many messages can you send in how much time? Make the appropriate changes in the calls, or ask them to increase the amount of messages you can send for a given time period.
Hope this helps!