What does the undocumented /c option do in regsvr32 - visual-studio

I am updating a native C++ DLL with COM components from Visual Studio 6.0 to Visual Studio 2019. The original project has a post build event to register the the DLL
regsvr32 /s /c my.dll
Looking at the help screen for regsvr32 the /c option is not listed and an online search and even Microsoft online documentation did not turn up anything on a /c option for regsvr32. I realize with VS2019 I can select the register output option under Linker Properties but I'd like to know what the reason was for the /c option in the original project.
The option /c does appear to be a valid since using it does not generate an error message whereas use of other invalid options does. The help screen above was generated with
regsvr32 /z my.dll

Prior to Windows 2000 regsvr32 /c used to send its output to the console (and VC++ 6 dates back to 1998, when NT 3.x/4.0 were still alive and well).
This was also mentioned in JSI Tip 6434 which corrects the "to the computer" typo in Q288373.
In Windows NT 4.0 and other previous operating systems, you could use the /C switch with Regsvr32.exe to send output to the console, which allowed you to script the process and test for the result. This functionality is no longer included in Windows NT 5.0 and higher.

Related

Can't use vsjitdebugger anymore to debug processes at startup

When I was working in versions of windows prior to Windows 10, I was able to get the debugger to be invoked when a particular executable was started. To do this I created the following batch file:
#echo off
>%temp%\output.reg echo Windows Registry Editor Version 5.00
>>%temp%\output.reg echo+
>>%temp%\output.reg echo [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Image File Execution Options\regsvr32.exe]
>>%temp%\output.reg echo "debugger"="vsjitdebugger.exe"
regedit /s %temp%\output.reg
del %temp\output.reg
And to stop it I used:
#echo off
>%temp%\output.reg echo Windows Registry Editor Version 5.00
>>%temp%\output.reg echo+
>>%temp%\output.reg echo [HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Image File Execution Options\regsvr32.exe]
>>%temp%\output.reg echo "debugger"=-
regedit /s %temp%\output.reg
del %temp\output.reg
Of course these files are used exclusively for regsvr32.exe. I have others for other executables.
However, when using this trick under Windows 10, it failed to work. I would get the error:
An error occurred while launching 'regsvr32 "my.dll"':
The Visual Studio Just-In-Time Debugger was not notified that the application correctly started.
Check the documentation index for 'Just-in-time debugging, errors' for more information.
I don't know what documentation index that it was referring to, but I figured that it was some permission issue, so I tried to change the settings on the vsjitdebugger.exe file to Run this program as an administrator, to which I got a different error dialog that said:
C:\WINDOWS\system32\regsvr32.exe
The requested operation requires elevation.
Now, if I were to open up a Administrator cmd window and use the command:
vsjitdebugger.exe regsvr32 "my.dll"
This does invoke the debugger at start up of the regsvr32.exe application. However, the point of this trick was to ensure that the debugger gets invoked when anything executes the application, which may not be under a cmd process that I am controlling.
So I have 2 questions.
Does anyone know of the document index that is being referred to in the error message?
How do I get this to work under Windows 10 Version 1709 (OS Build 16299.371)?
I had the same issue. No idea why, but apparently on Windows 10 it's necessary to configure something in the registry, which as far as I remember wasn't necessary before, or maybe happened automatically when installing Visual Studio.
It's mentioned here under "troubleshooting": https://learn.microsoft.com/en-us/visualstudio/debugger/debug-using-the-just-in-time-debugger#jit_errors
The fix is to add a DWORD Value of Auto, with Value data of 1, to the following registry keys:
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\AeDebug
(For 64-bit machines): HKEY_LOCAL_MACHINE\Software\WOW6432Node\Microsoft\Windows NT\CurrentVersion\AeDebug

VB6 compiling via console (vb.exe) compatibility issue on 64bit (works on 32bit?)

I'm using
cd C:\Program Files (x86)\Microsoft Visual Studio\VB98
vb6.exe /make Project1 /out %1
To basically compile my application, and I'm getting a compatibility issue (Saying doesn't work on my type of windows).
When compiling with the VB6 IDE (Make .exe) that works perfectly on my machine but this isn't, does anybody know how to fix this? Thanks
Error I receive when trying to open executable: "This version of this file is not compatible with the version of Windows you're running. Check your computer's system information to see whether you need a x86 32-bit or a x64 64-bit version of the program, the contact the software publisher".
& It's a standard EXE application also.
I've tried running it as a administrator, trouble shooting / changing the compatibility to windows XP service pack 2 & 3, still didn't work.
Work prefer a good fix to this, like if there's anything I can do via console as a option or something or some option or anything.
Cheers! Please help ASAP
From the discussion in the comments, I believe the answer here is as follows (as identified by GSerg):
The problem is your use of the /make switch on the command line. The documentation says this about /out:
Outputs errors to a file when used with the /make or /makedll switch.
So, if you used vb6.exe /make Project1 /out Project1.exe, then Project1.exe would actually be a text file containing the error output from the compiler and thus would not be an actual executable, even though it had an .exe extension.
You actually don't specify the output binary when you use /make. The help output from running VB6.exe /? is a little more explicit:
Tells Visual Basic to compile projectname and make an executable file
from it, using the existing settings stored in the project file.
VB remembers the last filename and directory you used for compiling your project in the IDE, and it stores that in the .vbp file:
ExeName32="Project1.exe"
Path32="..\output"
I use a batch file to handle this issue. It sets the path to include both the 32-bit and 64-bit versions of the Program Files directories. Then just reference 'vb6.exe' and the correct one will be pulled from your path.
set PATH=c:"\Program Files (x86)\Microsoft Visual Studio\VC98\bin"
set PATH=%PATH%;c:"\Program Files (x86)\Microsoft Visual Studio\VB98"
set PATH=%PATH%;c:"\Program Files\Microsoft Visual Studio\VC98\bin"
set PATH=%PATH%;c:"\Program Files\Microsoft Visual Studio\VB98"
vb6 /m foobar.vpb

VB6 - After compiled getting compatibility issue on Windows 7 64bit [duplicate]

I'm using
cd C:\Program Files (x86)\Microsoft Visual Studio\VB98
vb6.exe /make Project1 /out %1
To basically compile my application, and I'm getting a compatibility issue (Saying doesn't work on my type of windows).
When compiling with the VB6 IDE (Make .exe) that works perfectly on my machine but this isn't, does anybody know how to fix this? Thanks
Error I receive when trying to open executable: "This version of this file is not compatible with the version of Windows you're running. Check your computer's system information to see whether you need a x86 32-bit or a x64 64-bit version of the program, the contact the software publisher".
& It's a standard EXE application also.
I've tried running it as a administrator, trouble shooting / changing the compatibility to windows XP service pack 2 & 3, still didn't work.
Work prefer a good fix to this, like if there's anything I can do via console as a option or something or some option or anything.
Cheers! Please help ASAP
From the discussion in the comments, I believe the answer here is as follows (as identified by GSerg):
The problem is your use of the /make switch on the command line. The documentation says this about /out:
Outputs errors to a file when used with the /make or /makedll switch.
So, if you used vb6.exe /make Project1 /out Project1.exe, then Project1.exe would actually be a text file containing the error output from the compiler and thus would not be an actual executable, even though it had an .exe extension.
You actually don't specify the output binary when you use /make. The help output from running VB6.exe /? is a little more explicit:
Tells Visual Basic to compile projectname and make an executable file
from it, using the existing settings stored in the project file.
VB remembers the last filename and directory you used for compiling your project in the IDE, and it stores that in the .vbp file:
ExeName32="Project1.exe"
Path32="..\output"
I use a batch file to handle this issue. It sets the path to include both the 32-bit and 64-bit versions of the Program Files directories. Then just reference 'vb6.exe' and the correct one will be pulled from your path.
set PATH=c:"\Program Files (x86)\Microsoft Visual Studio\VC98\bin"
set PATH=%PATH%;c:"\Program Files (x86)\Microsoft Visual Studio\VB98"
set PATH=%PATH%;c:"\Program Files\Microsoft Visual Studio\VC98\bin"
set PATH=%PATH%;c:"\Program Files\Microsoft Visual Studio\VB98"
vb6 /m foobar.vpb

VB6 IDE cannot load MSCOMCTL.OCX after update KB 2687323

After windows update installed security update KB2687323, my VB6 project fails to load. Displayed error message is "'[project_vbp_path]/MSCOMCTL.OCX' could not be loaded--Continue Loading Project?". Note that the path in the messeage is the vbp file folder path instead of the control's registered path.
Details:
MSCOMCTL.OCX is registered in the usual system32 folder.
The executable produced by exactly the same project, an hour before the update runs fine and loads the updated MSCOMCTL.OCX (I have checked it with Process Explorer).
The security update description states that MSCOMCTL.OCX has a new fixed version. So I checked the project properties for "Upgrade ActiveX Controls" checkbox. I tried it both ways; checked and unchecked to no avail. VB6 IDE refused to load the upgraded OCX.
After hours of effort, system restore, register, unregister cycles and a night's sleep I have managed to pinpoint the problem. It turns out that the project file contains the below line:
Object={831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.0#0; MSCOMCTL.OCX
The version information "2.0" it seems was the reason of not loading. Changing it to "2.1" in notepad solved the problem:
Object={831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0; MSCOMCTL.OCX
So in a similar "OCX could not be loaded" situation one possible way of resolution is to start a new project. Put the control on one of the forms and check the vbp file with notepad to see what version it is expecting.
OR A MUCH EASIER METHOD:
(I have added this section after Bob's valuable comment below)
You can open your VBP project file in Notepad and find the nasty line that is preventing VB6 to upgrade the project automatically to 2.1 and remove it:
NoControlUpgrade=1
The problem has been resolved by running the following in elevated command prompt:
command :
cd C:\Windows\System32\
regtlib msdatsrc.tlb
or
cd C:\Windows\SysWOW64\
regtlib msdatsrc.tlb
I hope this helps.
The problem:
Microsoft Office 2010 products (or later) install updates that break compatibility of MSCOMCTL.ocx and COMCTL32.ocx. Unfortunately this affects many other programs such Visual Basic 6 SP6 and even Oracle Virtual Box v5. The actual problem is HKEY_CLASSES_ROOT\TypeLib\{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}\2.0 registry key. You can find detailed background information about this problem here.
Here is another working solution:
The solution assumes you have not damaged your registry by deleting, replacing and re-registering MSCOMCTL.ocx and COMCTL32.ocx without unregistering the Office patch files.
Create a batch file called fix.cmd and place the following commands in it:
regsvr32 /s /u %windir%\SysWOW64\comctl32.ocx
regsvr32 /s /u %windir%\SysWOW64\mscomctl.ocx
del /y %windir%\SysWOW64\comctl32.ocx
del /y %windir%\SysWOW64\mscomctl.ocx
msiexec /passive /norestart /i KB2708437.msi
msiexec /passive /a KB2708437.msi
regtlib %windir%\SysWOW64\msdatsrc.tlb
Download from Security update for Visual Basic 6.0 Service Pack 6: August 14, 2012 the msi file and rename it to KB2708437.msi.
Note: A direct link to the Service Pack 6 download is located HERE.
Run fix.cmd and the problem will be fixed!
What fix.cmd does is to properly unregister and then delete the current MSCOMCTL.ocx and COMCTL32.ocx files, and then apply the latest Visual Basic 6 SP6 rollup patch. In fact, the script enforces the patch to be installed and then re-installed by updating every file, regardless of version. Finally it registers msdatsrc.tlb type library.
Please let me know if this works for you.
======================================================================
Advanced Solution:
If however you have accidentally damaged your registry, you need to get as many versions of MSCOMCTL.ocx and COMCTL32.ocx you can find. Then you need to start from the newer version going back to the older and register and unregister the ocx files.
The latest version of MSCOMCTL.ocx is 6.1.98.39 (v2.1) of May 2012 which is more likely the one installed on your system and causing all your problems.
The oldest (legacy) version is that shipped with Visual Basic 6 on 1998 6.1.97.82 (v2.0), or the one shipped with an early service pack 6.1.97.86 on April 2005.
Example:
regsvr32 /s comctl32.6.0.98.34.ocx
regsvr32 /s /u comctl32.6.0.98.34.ocx
regsvr32 /s comctl32.6.0.81.6.ocx
regsvr32 /s /u comctl32.6.0.81.6.ocx
regsvr32 /s comctl32.6.0.81.5.ocx
regsvr32 /s /u comctl32.6.0.81.5.ocx
regsvr32 /s mscomctl.6.1.98.39.(2.1).ocx
regsvr32 /s /u mscomctl.6.1.98.39.(2.1).ocx
regsvr32 /s mscomctl.6.1.98.34.ocx
regsvr32 /s /u mscomctl.6.1.98.34.ocx
regsvr32 /s mscomctl.6.1.97.86.ocx
regsvr32 /s /u mscomctl.6.1.97.86.ocx
regsvr32 /s mscomctl.6.1.97.82.(2.0).ocx
regsvr32 /s /u mscomctl.6.1.97.82.(2.0).ocx
regsvr32 /s /u %windir%\SysWOW64\comctl32.ocx
regsvr32 /s /u %windir%\SysWOW64\mscomctl.ocx
del /q %windir%\SysWOW64\comctl32.ocx
del /q %windir%\SysWOW64\mscomctl.ocx
msiexec /passive /norestart /i KB2708437.msi
msiexec /passive /a KB2708437.msi
regtlib %windir%\SysWOW64\msdatsrc.tlb
WARNING:
Do not search the internet for those files. To find different version of the OCX files download and extract official Microsoft Installer packages such as the following:
2005 Apr - Microsoft KB896559
2008 Dec - Microsoft KB926857
2009 Apr - Microsoft KB957924
2012 May - Microsoft KB2708437
It is also recommended to run CCleaner version 4.0 or later to fix any other ActiveX related problems on your computer.
To Fix the Problem:
Make a Batch file with the following code:
#echo off
reg query "HKEY_CLASSES_ROOT\typelib\{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}\2.1"
if %errorlevel%==0 GOTO DELREGKEY
if %errorlevel%==1 GOTO REGISTEROCX
:DELREGKEY
reg delete hkcr\typelib\{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}\2.0 /f
:REGISTEROCX
if exist %systemroot%\SysWOW64\cscript.exe goto 64
%systemroot%\system32\regsvr32 /u mscomctl.ocx /s
%systemroot%\system32\regsvr32 mscomctl.ocx /s
exit
:64
%systemroot%\sysWOW64\regsvr32 /u mscomctl.ocx /s
%systemroot%\sysWOW64\regsvr32 mscomctl.ocx /s
exit
I use win7 and has same problem.
Today I solved this problem, through loading with many error with my project just give order to continue after that goto Project=> Component => Microsoft Windows Common Controls 6.0 (SP6) then save the project (file use was c:\windows\syswow64\mscomctl.ocx)
The solution for me is to install this VB6 patch. I'm on Server2008 (32-bit).
http://www.microsoft.com/en-us/download/details.aspx?id=10019
It makes me sad that we're still talking about this in 2014... but here it is. :)
From puetzk's comment: These are outdated: you want to be using Microsoft Visual Basic 6.0 Service Pack 6 Cumulative Update (kb957924).
I do not find NoControlUpgrade=1 on my vbp project.
Instead, I develop on both xp and windows7 x64. When I moved the project from window 7 to xp, the error occurred.
From what I find out, these are different:
Object={831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.0#0; MSCOMCTL.OCX
Object={831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.1#0; MSCOMCTL.OCX
I just changed the #2,1 back to #2.0 on the vbp file and it can run immediately.
These kind of problems occurred before, so hope Microsoft explain and solve them accordingly.
Thanks.
On some computers, I've found that the "2.0" version of MSCOMCTL.OCX has been added to the ActiveX KillBits list, and thus the control won't be allowed to load or run--even in design view. Updating to the "2.1" version will resolve this, and is the recommended solution.
In critical cases, where you have to run a program "now", or you don't have access to source code, or the control is used 400 times in a large modular project, you can use a "big hammer" method and update the registry to re-enable the control:
**
WARNING: Editing the Windows Registry in the wrong way can mess up your computer big time. If you're not sure what you're doing, please leave it alone, or get some schooling before you proceed.
**
The clear the KillBit:
Run Registry Editor (regedit.exe or regedt32.exe)
In the left-hand panel, navigate to key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Internet Explorer\ActiveX
Compatibility{BDD1F04B-858B-11D1-B16A-00C0F0283628}
In the right-hand panel, double-click on “Compatibility Flags”, change the value from Hex 0x400 (Decimal 1024) to 0, then click OK.
Launch the application that uses the "2.0" version of MSCOMCTL.OCX; it should run as designed.
The ActiveX KillBits list is intended to give Microsoft the means to disable controls that are deemed to be a security risk, and they've designed the mechanism such that the ActiveX KillBits list will be re-applied to the system at seemingly random times, in addition to when an Update is installed, so you'll need to plan for re-applying the registry change. Making a registry merge file works pretty well, but it's not something you want to do everytime the app runs, because it's not a quiet process (there are ways to do this quietly using Windows Scripting, but you'll have to learn that on your own). The KillBit is checked only when the control is requested by an application, so you're safe from resets once the application launches and loads the control.
You may try to check your registry
HKEY_LOCAL_MACHINE\SOFTWARE\Classes\TypeLib{831FDD16-0C5C-11D2-A9FC-0000F8754DA1}
If it is 2.1 version, it will cause cannot load MSCOMCTL.OCX issue.
You may restore to 2.0 verion (not only copy the file, you should unregiser 2.1 and register the restored file)
Or
You may try latest 2.2 version
https://support.microsoft.com/en-us/kb/3096896 (file date: 5-Nov-2015)
https://www.microsoft.com/en-us/download/details.aspx?id=50722
Some version information :
6.0.88.62 (2.0)
6.1.97.82 (2.0)
6.1.98.34 (2.1) <<< not work for me
6.1.98.46 (2.2)
Same problem with VBA Macros using MSCOMCTL.OCX.
Problem still unresolved with solutions like "reg/unreg mscomctl.ocx"
Used the Info above of Rumi.
Edited my *.dot file, search for #2.0#0, change it to #2.1#0
--> it worked
I had this problem and tried many different solutions. They didn't work for me although I think this error occurs for a couple of different reasons. My solution is in my answer to this question here:
https://stackoverflow.com/a/15785253/2240058
Its worth a try if nothing else is working for you.
This problem mysteriously appeared for me today. I hadn't done any Windows updates, so I don't know the cause.
This fixed it (in elevated command prompt):
regtlibv12.exe msdatsrc.tlb
For me, this solution worked like a charm:
http://home.pacific.net.hk/~edx/bin/readmeocx.txt
Fix these two lines like that:
Object={F9043C88-F6F2-101A-A3C9-08002B2F49FB}#1.2#0; COMDLG32.OCX
Object={831FDD16-0C5C-11D2-A9FC-0000F8754DA1}#2.0#0; MSCOMCTL.OCX
Search the files (.vbp and .frm) for lines like this:
Begin ComctlLib.ImageList ILTree
Begin ComctlLib.StatusBar StatusBar1
Begin ComctlLib.Toolbar Toolbar1`
The lines may be like this:
Begin MSComctlLib.ImageList ILTree
Begin MSComctlLib.StatusBar StatusBar1
Begin MSComctlLib.Toolbar Toolbar1`
I recently put all my source on a windows 8 32 box. Had the issues loading mscomctl.ocx with existing projects.
I created a new project and add the common control (all). save the project and reloaded it no problem.
when you compare the project headers new vs old the old one uses reference=*\blah blah. I found removing this a replacing it with the Object={blah} sorted out the problem.
I continued to have problems after trying the things suggested here. In the end, it turned out that I had the wrong version of mscomctl.ocx in my SysWOW64 folder. I found the following versions kicking around:
Mar. 09, 2004 01:00 AM 1,081,616 mscomctl.ocx
Jun. 06, 2012 07:59 PM 1,070,152 mscomctl.ocx
Dec. 08, 2015 03:57 AM 1,070,232 MSCOMCTL.OCX
Getting the last one (1,070,232) solved this problem for me.
I had similar trouble, have a program running for last 10 years written in VB6, now client wanted to make some major modifications, and all my machines which are now windows 10; failed to open the project, it was always that nasty mscomctl.ocx error. I had done lot of things but could not solve the problem. Then I thought the easy way around, I downloaded the latest mscomctl (
Then opened a new project, added all the components like mscomctl, activx controls etc, saved it and opened this newly created project file in Notepad, then copied the exact details and replaced in the original project.... and bingo! The old project opened up normally without any fuss! I hope this experience will help someone.
In my case didn't work any solution above. Near to give up, removed any reference (using Arvo Bowen's fix.cmd file) and tried pasting mscomctl.ocx (version 6.1.97.86) in C:\Program Files (x86)\Microsoft Visual Studio\VB98 folder. It worked finally after more than 4 or 5 hours fighting for a solution.

Signing assembly Access Is Denied

I've recently upgraded to WIndows 7. When I try to sign the assembly in VS2010 I get an "Access is denied" error. I am logged as admin so I'm puzzled. What service account does VS uses that I should elevate its privilages?
Thanks,
Risho
I don't know if it's Window 7 or the company policy, but I had to take ownership of the C:\Users\All Users\Application Data\Microsoft\Crypto\RSA\MachineKeys folder and give myself full control. This corrected the issue.
Solution:
Run the following command from Administrator command prompt:
For 64-bit systems:
reg add HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Microsoft\StrongName /v MachineKeyset /t REG_DWORD /d 0
For 32-bit systems:
reg add HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\StrongName /v MachineKeyset /t REG_DWORD /d 0
The change affects immediately.
Why this happens:
MS Assembly Linker ALINK (AL.EXE) used by Visual Studio to sign assemblies creates a temporary crypto key during its work. Actually it uses some internal CLR functions for this, and the problem is that CRYPT_MACHINE_KEYSET flag is used by default. This requires elevation, and that's why running VS "as Administrator" works.
But, fortunately, I found that CLR has a global flag for StrongName signing, and it's stored in the system registry under
HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\StrongName
and is controlled by DWORD value
MachineKeyset.
0 - use current user key set
1 - use machine key set (this is default)
Visual Studio is a 32-bit app and uses 32-bit version of AL.EXE for build. So on 64-bit systems it's subject to registry redirection, and the flag is located under the key
HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Microsoft\StrongName
It works on my VS2019, Win10, and .Net framework 4.8, but I didn't test it on previous versions though.
For windows 10 and VS 2015, I have to run VS as administrator.
On Win10 I gave the user who im starting Visual Studio with, rights to read, write, run, change and display for the folder:
C:\ProgramData\Microsoft\Crypto