I want to restart PrTomcat service in Primary node on failover using generic script in windows failover cluster with below code but tomcat is taking some time to stop (5 seconds to 150 seconds sometimes) and below code is failing to restart the service, any idea? As per cluster logs only one entry coming from script and no error 01-11-2021 23:18:07 StopService PrTomcat Stop Pending
Function Online( )
On Error Resume Next
'
' For the local strComputer only...
'
strComputer = "."
strServiceName = "PrTomcat"
StopService strComputer, strServiceName
StartService strComputer, strServiceName
Online = true
End Function
Function LooksAlive( )
LooksAlive = true
End Function
Function IsAlive( )
IsAlive = true
End Function
Sub StopService(strComputer, strServiceName)
Dim cimv2, oService, Result
'Get the WMI administration object
Set cimv2 = GetObject("winmgmts:{impersonationLevel=impersonate}!\\" & _
strComputer & "\root\cimv2")
'Get the service object
Set oService = cimv2.Get("Win32_Service.Name='" & strServiceName & "'")
'Check base properties
If Not oService.Started Then
' the service is Not started
Resource.LogInformation "The service " & strServiceName & " is Not started"
exit Sub
End If
If Not oService.AcceptStop Then
' the service does Not accept stop command
Resource.LogInformation "The service " & strServiceName & " does Not accept stop command"
exit Sub
End If
'Stop the service
Result = oService.StopService
If 0 <> Result Then
Resource.LogInformation "Stop " & strServiceName & " error: " & Result
exit Sub
End If
Do While oService.Started
'get the current service state
Set oService = cimv2.Get("Win32_Service.Name='" & strServiceName & "'")
Resource.LogInformation now & " StopService PrTomcat " & oService.State
Wscript.Sleep 15000
Loop
End Sub
Sub StartService(strComputer, strServiceName)
Dim cimv2, oService, Result
'Get the WMI administration object
Set cimv2 = GetObject("winmgmts:{impersonationLevel=impersonate}!\\" & _
strComputer & "\root\cimv2")
'Get the service object
Set oService = cimv2.Get("Win32_Service.Name='" & strServiceName & "'")
Set oService = cimv2.Get("Win32_Service.Name='" & strServiceName & "'")
Do While StrComp(oService.State,"Stop Pending",1) = 0
Wscript.Sleep 15000
Resource.LogInformation "The service " & strServiceName & " Stop Pending."
Loop
'Start the service
Result = oService.StartService
If 0 <> Result Then
Resource.LogInformation "Start " & strServiceName & " error:" & Result
exit Sub
End If
Do While InStr(1,oService.State,"running",1) = 0
'get the current service state
Set oService = cimv2.Get("Win32_Service.Name='" & strServiceName & "'")
Resource.LogInformation now & " StartService PrTomcat " & oService.State
Wscript.Sleep 200
Loop
End Sub
Related
I have this code to remotely kill a certain process on 5 servers. My problem is that i want to cut it short and kill the process in all servers in 1 click. The code now asks if i am sure i want to kill the process, then kills the process, then asks if i want to proceed to the next server. i would like to just have a messge saying, "Killing process on all servers" and done
`Option Explicit
Dim objWMIService, objProcess, colProcess
Dim strProcessKill, item
Dim strComputer(4)
Dim ans, killFLag
strComputer(0) = "server1"
strComputer(1) = "server2"
strComputer(2) = "server3"
strComputer(3) = "server4"
strComputer(4) = "server5"
strProcessKill = "'notepad.exe'"
For item = 0 To 4 Step 1
if MsgBox("Are you sure you want to kill " & strProcessKill & " on " & strCOmputer(item) & "?" , vbYesNo + vbQuestion) = vbYes then
killFLag = 1
end if
if KillFlag = 1 then
msgbox "KILLING PROCESS ON" & strComputer(item)
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer(item) & "\root\cimv2")
Set colProcess = objWMIService.ExecQuery _
("Select * from Win32_Process Where Name = " & strProcessKill)
For Each objProcess in colProcess
objProcess.Terminate()
Next
WSCript.Echo "Just killed process " & strProcessKill & " on " & strComputer(item)
else
WScript.Quit
end if
Next`
Move the for loop down so that you are not prompted for each server. Something like this should work
Option Explicit
Dim objWMIService, objProcess, colProcess
Dim strProcessKill, item
Dim strComputer(4)
Dim ans, killFLag
strComputer(0) = "server1"
strComputer(1) = "server2"
strComputer(2) = "server3"
strComputer(3) = "server4"
strComputer(4) = "server5"
strProcessKill = "'notepad.exe'"
if MsgBox("Are you sure you want to kill " & strProcessKill & " on all servers?" , vbYesNo + vbQuestion) = vbYes then
killFLag = 1
end if
if KillFlag = 1 then
msgbox "KILLING PROCESS ON ALL SERVERS"
For item = 0 To 4 Step 1
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" & strComputer(item) & "\root\cimv2")
Set colProcess = objWMIService.ExecQuery _
("Select * from Win32_Process Where Name = " & strProcessKill)
For Each objProcess in colProcess
objProcess.Terminate()
Next
next
msgBox "Done"
else
WScript.Quit
end if
I am running various VBS scripts on our clients using Group Policy. On most clients this works fine. But on my computer (the one I created the scripts on), I always have multiple instances of MSE7 running after booting my computer - one for each of the VBS scripts I have deployed via Group Policy.
Can anyone help me understand why this is happening and / or how to stop it!
Thanks.
Andrew
With this script you can find any process by its commandline and choose to kill them. Just give a try !
Option Explicit
Dim Titre,Copyright,fso,ws,NomFichierLog,temp,PathNomFichierLog,OutPut,Count
If AppPrevInstance() Then
MsgBox "There is an existing proceeding !" & VbCrLF & CommandLineLike(WScript.ScriptName),VbExclamation,"There is an existing proceeding !"
WScript.Quit
Else
Copyright = "[© Hackoo © 2015 ]"
Set fso = CreateObject("Scripting.FileSystemObject")
Set ws = CreateObject( "Wscript.Shell" )
NomFichierLog="Killed_Process.txt"
temp = ws.ExpandEnvironmentStrings("%temp%")
PathNomFichierLog = temp & "\" & NomFichierLog
Set OutPut = fso.CreateTextFile(temp & "\" & NomFichierLog,1)
Call Find("wscript.exe")
Call Explorer(PathNomFichierLog)
End If
'***************************************************************************************************
Function Explorer(File)
Dim ws
Set ws = CreateObject("wscript.shell")
ws.run "Explorer "& File & "\",1,True
end Function
'***************************************************************************************************
Sub Find(MyProcess)
Dim colItems,objItem,Processus,Question
Titre = " Process "& DblQuote(MyProcess) &" running "
Set colItems = GetObject("winmgmts:").ExecQuery("Select * from Win32_Process " _
& "Where Name like '%"& MyProcess &"%' AND NOT commandline like " & CommandLineLike(WScript.ScriptFullName) & "",,48)
Count = 0
For Each objItem in colItems
Count= Count + 1
Processus = objItem.CommandLine
Question = MsgBox ("Would do you like to kill this script : " & DblQuote(Processus) & " ?" ,VBYesNO+VbQuestion,Titre+Copyright)
If Question = VbYes then
objItem.Terminate(0)'To kill the process
OutPut.WriteLine Processus
else
Count= Count - 1 'decrementing the count of -1
End if
Next
OutPut.WriteLine String(100,"*")
OutPut.WriteLine count & Titre & "were killed"
OutPut.WriteLine String(100,"*") & VbCrLF
End Sub
'**************************************************************************
Function DblQuote(Str)
DblQuote = Chr(34) & Str & Chr(34)
End Function
'**************************************************************************
Function AppPrevInstance()
With GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\.\root\cimv2")
With .ExecQuery("SELECT * FROM Win32_Process WHERE CommandLine LIKE " & CommandLineLike(WScript.ScriptFullName) & _
" AND CommandLine LIKE '%WScript%' OR CommandLine LIKE '%cscript%'")
AppPrevInstance = (.Count > 1)
End With
End With
End Function
'**************************************************************************
Function CommandLineLike(ProcessPath)
ProcessPath = Replace(ProcessPath, "\", "\\")
CommandLineLike = "'%" & ProcessPath & "%'"
End Function
'**************************************************************************
I am new to VBS scripting and I am wanting to script the stopping of Windows services other than a core set of services. I have currently written a bit of code that will query all local services and output to a text file their running state, I then wish to read from an input file a list of core services NOT to stop however to stop the rest of the services running on that machine. I would like this to be a generic input file so if a service is listed however is not installed on the server for it to continue onto the next service to stop.
Not sure how to proceed with this, would I need to read the input file into an array then do an IF statement to say if objService.Name not equal to the array (somehow) then to stop the service?
Code below - thanks in advance for any assistance/tips
Const ForAppending = 8
strComputer = "."
strLogPath = "C:\Scripts"
strServicesLog = strLogPath & Replace(Wscript.ScriptName,".vbs","") & ".txt"
Set objWMISvc = GetObject( "winmgmts:\\.\root\cimv2" )
Set colItems = objWMISvc.ExecQuery( "Select * from Win32_ComputerSystem", , 48)
' // Create Output Logs folder for script
Set objFS = CreateObject("Scripting.FileSystemObject")
Set objTS = objFS.CreateTextFile(strServicesLog, True)
objTS.Write "******************************************************************" & vbcrlf
objTS.Write (Replace(Wscript.ScriptName,".vbs","") & " audit log") & vbcrlf
objTS.Write ("Execution Start: " & FormatDateTime(Now(),2) & " " &
FormatDateTime(Now(),3)) & vbcrlf
For Each objItem in colItems
strComputerName = objItem.Name
objTS.Write vbCrlf & "Server Name: " & strComputerName & vbCrlf
Next
Set objWMIService = GetObject("winmgmts:" & "{impersonationLevel=impersonate}!\\" &
strComputer & "\root\cimv2")
Set colRunningServices = objWMIService.ExecQuery _
("Select * from Win32_Service")
For Each objService in colRunningServices
objTS.Write "Display Name: " & vbTab & (objService.DisplayName) & vbCrlf
objTS.Write "Service Name: " & vbTab & (objService.Name) & vbCrlf
objTS.Write "Service State: " & vbTab & (objService.State) & vbCrlf
objTS.Write "Start Mode: " & vbTab & (objService.StartMode) & vbCrlf
objTS.WriteLine
Next
objTS.Close
You could read your list of services into a Dictionary object. The Dictionary class has an Exists() method that you can use to test if a string/key exists.
Here's how to read a list of strings (services) from a file named c:\input.txt into a dictionary:
Set d = CreateObject("Scripting.Dictionary")
Set objFileIn = objFS.OpenTextFile("c:\input.txt")
Do Until objFileIn.AtEndOfStream
strService = objFileIn.ReadLine()
If Len(strService) > 0 Then If Not d.Exists(strService) Then d.Add strService, ""
Loop
Later, when you're iterating the list of services on the computer, check the service name against your dictionary:
For Each objService in colRunningServices
' If this service is not in the list of core services, stop it...
If Not d.Exists(objService.Name) Then objService.StopService
Next
I am trying to run following VB Script to run command on remote machine. I want this script to wait until command is executed completely.
Here is my code:
Function RemoteExecute(strServer, strUser, strPassword, strCommand,pro)
Dim objLocator , objWMIService
wbemImpersonationLevelImpersonate = 3
wbemAuthenticationLevelPktPrivacy = 6
RemoteExecute = -1
Set objLocator = CreateObject("WbemScripting.SWbemLocator")
On Error Resume Next
Set objWMIService = objLocator.ConnectServer(strServer,"root\cimv2", strUser,strPassword)
objWMIService.Security_.ImpersonationLevel = wbemImpersonationLevelImpersonate
objWMIService.Security_.AuthenticationLevel = wbemAuthenticationLevelPktPrivacy
If Err.Number <> 0 Then
WScript.Echo "Failed to connect to " &strServer, "Error # " & CStr(Err.Number) & " " & Err.Description & vbcrlf & _
"Please check if " & strServer & " is pingable from this client & credentials are correct"
Err.Clear
On Error GoTo 0
RemoteExecute = -1
Set objWMIService = nothing
Set objLocator = nothing
Exit function
end if
' Configure the process to show a window
Set objStartup = objWMIService.Get("Win32_ProcessStartup")
Set objConfig = objStartup.SpawnInstance_
objConfig.ShowWindow = SW_NORMAL
Set Process = objWMIService.Get("Win32_Process")
'Process.Create Syntax: '
' uint32 Create(
'[in] string CommandLine,
'[in] string CurrentDirectory,
'[in] Win32_ProcessStartup ProcessStartupInformation,
'[out] uint32 ProcessId
');
'Return code Description
'0 Successful Completion
'2 Access Denied
'3 Insufficient Privilege
'8 Unknown failure
'9 Path Not Found
'21 Invalid Parameter
intReturn = Process.Create(strCommand,NULL, objConfig, intProcessID)
If intReturn <> 0 Then
Wscript.Echo "Process could not be created." & _
vbNewLine & "Command line: " & strCommand & _
vbNewLine & "Return value: " & intReturn
Wscript.Quit
Else
Wscript.Echo "Process created." & _
vbNewLine & "Command line: " & strCommand & _
vbNewLine & "Process ID: " & intProcessID
RemoteExecute = intProcessID
End If
' Set objWMIService = GetObject("winmgmts:\\" & strServer & "\root\cimv2")
Set colMonitoredProcesses = objWMIService.ExecNotificationQuery_("SELECT *" +" FROM __InstanceDeletionEvent " +"WITHIN 5 WHERE TargetInstance ISA 'Win32_Process' " )
Do
Set objProcess = colMonitoredProcesses.NextEvent
Wscript.Echo objProcess.TargetInstance.Name
Wscript.Echo objProcess.TargetInstance.ExecutablePath
Wscript.Echo "1"
Wscript.Echo "proc:" & objProcess.TargetInstance.ProcessID
Wscript.Echo "int:" & intProcessID
If objProcess.TargetInstance.ProcessID = intProcessID Then
Wscript.Echo "I will end the monitoring of the process "
Wscript.Echo pro & objProcess.TargetInstance.Name
Exit Do
end If
Loop
Set objWMIService = nothing
Set objLocator = nothing
End Function
strServer = WScript.Arguments.Item(0)
strUser = WScript.Arguments.Item(1)
strPassword = WScript.Arguments.Item(2)
strCommand = WScript.Arguments.Item(3)
pro = WScript.Arguments.Item(4)
Call RemoteExecute(strServer, strUser, strPassword, strCommand,pro)
But problem I am facing is that, script run the process in background but not waiting for it.
Another point that I do not understand is, when try to echo following:
Wscript.Echo objProcess.TargetInstance.Name
Wscript.Echo objProcess.TargetInstance.ExecutablePath
Wscript.Echo "proc:" & objProcess.TargetInstance.ProcessID
it does no echo anything, whereas following are properly echoed with a nice pop up
Wscript.Echo "1"
Wscript.Echo "int:" & intProcessID
Can someone please resolve my problem, may be this problem is naive for someone, sorry I am naive here.
I have a couple questions and am hoping this is the correct place.
basically what i want to do is to be able to remotely get info about a domain computer.
i have 3 seperate scripts that give me 1( IP configuration, comp name ... ), 2 ( installed software ) and 3 ( mapped drives ).
the first two ask for the IP/computer name and the 3rd i have to input that into the script... i would like to only have to input the IP address once and have it work for all 3
secondly i would like the output file that this info is put into to be named like the installed software script does and then just have the other two scripts add ( ammend ) to the already created output.
I am super new to vbs so any help would be awesome
SCRIPT 1 ( gets IP configuration )
dim strComputer 'for computer name or IP
dim colAdapters 'collection of adapters
Set objFSO = CreateObject("Scripting.FileSystemObject")
Set objFile = objFSO.CreateTextFile("output.txt", True)
strComputer = ""
'open a dialog box asking for the computer name/IP
do
strComputer = inputbox( "Please enter a computername/IP, or . for local computer", "Input" )
Loop until strComputer <> "" 'run until a name/IP is entered
Set objWMIService = GetObject ("winmgmts:" & "!\\" & strComputer & "\root\cimv2") 'open the WMI service on the remote PC
Set colAdapters = objWMIService.ExecQuery ("Select * from Win32_NetworkAdapterConfiguration Where IPEnabled = True")
'go through the list of adapters and gather data
For Each objAdapter in colAdapters
objFile.Writeline "Host name: " & objAdapter.DNSHostName
objFile.Writeline "DNS domain: " & objAdapter.DNSDomain
objFile.Writeline "DNS suffix search list: " & objAdapter.DNSDomainSuffixSearchOrder
objFile.Writeline "Description: " & objAdapter.Description
objFile.Writeline "Physical address: " & objAdapter.MACAddress
objFile.Writeline "DHCP enabled: " & objAdapter.DHCPEnabled
If Not IsNull(objAdapter.IPAddress) Then
For i = LBound(objAdapter.IPAddress) To UBound(objAdapter.IPAddress)
objFile.Writeline "IP address: " & objAdapter.IPAddress(i)
Next
End If
If Not IsNull(objAdapter.IPSubnet) Then
For i = LBound(objAdapter.IPSubnet) To UBound(objAdapter.IPSubnet)
objFile.Writeline "Subnet: " & objAdapter.IPSubnet(i)
Next
End If
If Not IsNull(objAdapter.DefaultIPGateway) Then
For i = LBound(objAdapter.DefaultIPGateway) To UBound(objAdapter.DefaultIPGateway)
objFile.Writeline "Default gateway: " & objAdapter.DefaultIPGateway(i)
Next
End If
objFile.Writeline "DHCP server: " & objAdapter.DHCPServer
If Not IsNull(objAdapter.DNSServerSearchOrder) Then
For i = LBound(objAdapter.DNSServerSearchOrder) To UBound(objAdapter.DNSServerSearchOrder)
objFile.Writeline "DNS server: " & objAdapter.DNSServerSearchOrder(i)
Next
End If
objFile.Writeline "Primary WINS server: " & objAdapter.WINSPrimaryServer
objFile.Writeline "Secondary WINS server: " & objAdapter.WINSSecondaryServer
objFile.Writeline "Lease obtained: " & objAdapter.DHCPLeaseObtained
objFile.Writeline "Lease expires: " & objAdapter.DHCPLeaseExpires
Next
SCRIPT 2 ( gets installed software )
Option Explicit
Dim sTitle
sTitle = "InstalledPrograms.vbs by Bill James"
Dim StrComputer
strComputer = InputBox("Enter I.P. or name of computer to check for " & _
"installed software (leave blank to check " & _
"local system)." & vbcrlf & vbcrlf & "Remote " & _
"checking only from NT type OS to NT type OS " & _
"with same Admin level UID & PW", sTitle)
If IsEmpty(strComputer) Then WScript.Quit
strComputer = Trim(strComputer)
If strComputer = "" Then strComputer = "."
'Wscript.Echo GetAddRemove(strComputer)
Dim sCompName : sCompName = GetProbedID(StrComputer)
Dim sFileName
sFileName = sCompName & "_" & GetDTFileName() & "_Software.txt"
Dim s : s = GetAddRemove(strComputer)
If WriteFile(s, sFileName) Then
'optional prompt for display
If MsgBox("Finished processing. Results saved to " & sFileName & _
vbcrlf & vbcrlf & "Do you want to view the results now?", _
4 + 32, sTitle) = 6 Then
WScript.CreateObject("WScript.Shell").Run sFileName, 9
End If
End If
Function GetAddRemove(sComp)
'Function credit to Torgeir Bakken
Dim cnt, oReg, sBaseKey, iRC, aSubKeys
Const HKLM = &H80000002 'HKEY_LOCAL_MACHINE
Set oReg = GetObject("winmgmts:{impersonationLevel=impersonate}!\\" & _
sComp & "/root/default:StdRegProv")
sBaseKey = "SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\"
iRC = oReg.EnumKey(HKLM, sBaseKey, aSubKeys)
Dim sKey, sValue, sTmp, sVersion, sDateValue, sYr, sMth, sDay
For Each sKey In aSubKeys
iRC = oReg.GetStringValue(HKLM, sBaseKey & sKey, "DisplayName", sValue)
If iRC <> 0 Then
oReg.GetStringValue HKLM, sBaseKey & sKey, "QuietDisplayName", sValue
End If
If sValue <> "" Then
iRC = oReg.GetStringValue(HKLM, sBaseKey & sKey, _
"DisplayVersion", sVersion)
If sVersion <> "" Then
sValue = sValue & vbTab & "Ver: " & sVersion
Else
sValue = sValue & vbTab
End If
iRC = oReg.GetStringValue(HKLM, sBaseKey & sKey, _
"InstallDate", sDateValue)
If sDateValue <> "" Then
sYr = Left(sDateValue, 4)
sMth = Mid(sDateValue, 5, 2)
sDay = Right(sDateValue, 2)
'some Registry entries have improper date format
On Error Resume Next
sDateValue = DateSerial(sYr, sMth, sDay)
On Error GoTo 0
If sdateValue <> "" Then
sValue = sValue & vbTab & "Installed: " & sDateValue
End If
End If
sTmp = sTmp & sValue & vbcrlf
cnt = cnt + 1
End If
Next
sTmp = BubbleSort(sTmp)
GetAddRemove = "INSTALLED SOFTWARE (" & cnt & ") - " & sCompName & _
" - " & Now() & vbcrlf & vbcrlf & sTmp
End Function
Function BubbleSort(sTmp)
'cheapo bubble sort
Dim aTmp, i, j, temp
aTmp = Split(sTmp, vbcrlf)
For i = UBound(aTmp) - 1 To 0 Step -1
For j = 0 to i - 1
If LCase(aTmp(j)) > LCase(aTmp(j+1)) Then
temp = aTmp(j + 1)
aTmp(j + 1) = aTmp(j)
aTmp(j) = temp
End if
Next
Next
BubbleSort = Join(aTmp, vbcrlf)
End Function
Function GetProbedID(sComp)
Dim objWMIService, colItems, objItem
Set objWMIService = GetObject("winmgmts:\\" & sComp & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select SystemName from " & _
"Win32_NetworkAdapter",,48)
For Each objItem in colItems
GetProbedID = objItem.SystemName
Next
End Function
Function GetDTFileName()
dim sNow, sMth, sDay, sYr, sHr, sMin, sSec
sNow = Now
sMth = Right("0" & Month(sNow), 2)
sDay = Right("0" & Day(sNow), 2)
sYr = Right("00" & Year(sNow), 4)
sHr = Right("0" & Hour(sNow), 2)
sMin = Right("0" & Minute(sNow), 2)
sSec = Right("0" & Second(sNow), 2)
GetDTFileName = sMth & sDay & sYr & "_" & sHr & sMin & sSec
End Function
Function WriteFile(sData, sFileName)
Dim fso, OutFile, bWrite
bWrite = True
Set fso = CreateObject("Scripting.FileSystemObject")
On Error Resume Next
Set OutFile = fso.OpenTextFile(sFileName, 2, True)
'Possibly need a prompt to close the file and one recursion attempt.
If Err = 70 Then
Wscript.Echo "Could not write to file " & sFileName & ", results " & _
"not saved." & vbcrlf & vbcrlf & "This is probably " & _
"because the file is already open."
bWrite = False
ElseIf Err Then
WScript.Echo err & vbcrlf & err.description
bWrite = False
End If
On Error GoTo 0
If bWrite Then
OutFile.WriteLine(sData)
OutFile.Close
End If
Set fso = Nothing
Set OutFile = Nothing
WriteFile = bWrite
End Function
SCRIPT 3 ( gets mapped drives )
Set objFSO = CreateObject("Scripting.FileSystemObject")
Set objFile = objFSO.CreateTextFile("mappedoutput.txt", True)
' List Mapped Network Drives
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_MappedLogicalDisk")
For Each objItem in colItems
objFile.Writeline "Compressed: " & objItem.Compressed
objFile.Writeline "Description: " & objItem.Description
objFile.Writeline "Device ID: " & objItem.DeviceID
objFile.Writeline "File System: " & objItem.FileSystem
objFile.Writeline "Free Space: " & objItem.FreeSpace
objFile.Writeline "Maximum Component Length: " & objItem.MaximumComponentLength
objFile.Writeline "Name: " & objItem.Name
objFile.Writeline "Provider Name: " & objItem.ProviderName
objFile.Writeline "Session ID: " & objItem.SessionID
objFile.Writeline "Size: " & objItem.Size
objFile.Writeline "Supports Disk Quotas: " & objItem.SupportsDiskQuotas
objFile.Writeline "Supports File-Based Compression: " & _
objItem.SupportsFileBasedCompression
objFile.Writeline "Volume Name: " & objItem.VolumeName
objFile.Writeline "Volume Serial Number: " & objItem.VolumeSerialNumber
objFile.Writeline
Next
Again thank you
Can you put all the three scripts as 1 single script? In that case, you will need to input the IP address only once.
Or else write another script which will ask for the IP address and call these scripts by using cscript and passing the IPaddress to them as a parameter. Try this code for that:
strcomputer = inputbox("Enter the IP address")
set obj1 = createobject("wscript.shell")
set obj2 = createobject("wscript.shell")
set obj3 = createobject("wscript.shell")
pgm1 = "cscript script1.vbs " & strcomputer
pgm2 = "cscript script2.vbs " & strcomputer
pgm3 = "cscript script3.vbs " & strcomputer
obj1.run pgm1,3,true
obj2.run pgm2,3,true
obj3.run pgm3,3,true
set obj1 = nothing
set obj2 = nothing
set obj3 = nothing
In above code, script1.vbs, script2.vbs, script3.vbs are your 3 scripts and you are executing them one by one using a new script.
In script1.vbs, add this line of code :
strcomputer = wscript.Arguments.item(0)
It will store the 1rst argument that you have passed from your new script to script1.vbs, into the variable 'strcomputer'(in your case, the IP address).
Similarly, in both script2.vbs and script3.vbs also, add the statement
strcomputer = wscript.Arguments.item(0)
Regarding your output file, I am not sure what you are asking for. Maybe this can help:
Use the below to write to a file (overwrites if data is already present):
Set fso1 = CreateObject("Scripting.FileSystemObject" )
Set file1 = fso1.OpenTextFile("C:\New\textfile1.txt",2,true)
Use the below to add data or append to a file (does NOT overwrite):
Set fso1 = CreateObject("Scripting.FileSystemObject" )
Set file1 = fso1.OpenTextFile("C:\New\textfile1.txt",8,true)
Use the below to read from a file:
Set fso1 = CreateObject("Scripting.FileSystemObject" )
Set file1 = fso1.OpenTextFile("C:\New\textfile1.txt",1,true)